User manual

WARNING: THIS APPLIANCE MUST BE EARTHED.
o This appliance must be wired into a 30 A double pole switched
fused spur outlet, having 3 mm contact separation and placed in
an easily accessible position adjacent to the appliance. It should
not be located above the appliance and no more than 1.25m
away from it.
o The spur outlet must still be accessible even when your hob is
located in its operating position.
o Cable type: H05 RRF 3 core x 6 mm²
Connecting the mains supply cable
o The mains terminal block is located on the underside of the hob
and the terminals are accessible by removing the terminal block
cover by removing the cover screw.
o The cable connections must be in accordance with the diagram
located on the bottom of the hob.
o The brass links must be positioned as
marked in the diagram opposite and
once established ALL terminal screws
must be tightened down firmly.
o If when the hob is first switched
on, only two of the zones work, you
should recheck that the terminal
screws are all fully tightened
between the links. This should be
done before contacting the
Baumatic Customer Care
Department.
17