User manual
33
Butane
(G30)
30 65 127 -
Propane
(G31)
37 65 125 -
Natural
(G20)
20 115 - 286
Butane
(G30)
30 85 254 -
Rapid
Propane
(G31)
37 85 250 -
3.00 1.05
Natural
(G20)
20 135 - 286
Butane
(G30)
30 95 218 -
Wok
Propane
(G31)
37 95 214 -
3.50 1.80
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section on the next page.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
o Light the burner and set the
knob at the minimum
position.
o Remove the knob from the
tap and place a small bladed
screwdriver in the centre of
the tap shaft.
o Unscrew the adjusting screw, in order to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.