User manual
36
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
o Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does then remove
the control knob and make further adjustments to the gas
flow, testing it again once the adjustment has been made.
o IMPORTANT: On completion carry out a gas tightness
test.
Fitting a stability chain
IMPORTANT: It is a legal requirement for your
GASSAFE registered installer to fit a stability chain.
The stability hook should be securely fixed to the fabric of the building,
in an adjacent position to the safety chain at the rear of the appliance.