User manual

24
External ducting
o Connect the spigot to the top of the cooker hood, and then
connect a 125 mm ducting hose to the coupling (please note that
the ducting hose is not supplied with the appliance).
o The other end of the ducting hose should be connected to a
discharge outlet that is suitable for cooking vapours. It should
have a cross section of at least 150 cm².
o The maximum distance between the coupling and your discharge
outlet should be 3 metres, with one 90 degree bend.
o For each additional 90 degree bend that is made, the maximum
distance between the coupling and your discharge outlet is
reduced by 1 metre.
Troubleshooting
IMPORTANT: If your cooker hood appears not to be operating
properly, before contacting Baumatic Customer Care, please
refer to the checklist below.
My cooker hood will not start.
o Check that the hood is connected to the electricity supply.
o Check that the fan speed control is set correctly.
My cooker hood is not working effectively.
o The fan speed is not set high enough.
o The grease filters are dirty and require cleaning.
o The kitchen is not well ventilated enough.
o If the hood is set up for recirculation mode, check that the
carbon filters do not need replacing.
o If the hood is set up for extraction mode, check that the ducting
hose and discharge outlet are not blocked.