Gas adjustment (Conversion to LPG and gas adjustment)
IMPORTANT: Your appliance must be disconnected from the
electric and gas supply before completing this process.
Power inputs
Natural Gas LPG
Oven 2.74 kW (injector size 115) 2.74 kW (injector size 80)
Grill 2.40 kW (injector size 115)
2.40 kW (injector size 80)
Gas details
Gas Connection Type: 1/2” BSP male thread
Gas Type (Natural Gas G20): 20 mbar
Primary air gap (Natural Gas G20): 1.0 mm
Gas Type (LPG G30/31): 28/37 mbar
Primary air gap (LPG G30/31): 1.0 mm
o Open the door of the oven.
Unscrew the fixing screws and
then remove the base of the oven
cavity (as shown opposite).
27