o Re-fix the grill burner, no further adjustments are necessary.
o Remove the control
panel cover from the
top of the appliance.
o Remove the oven
control knobs and
then undo the two
fixing rings that are
exposed underneath,
by turning them anti-
clockwise.
o Disconnect the neon lamp at the rear of the fascia and then
remove the control panel front. Then refit the thermostat control
knob.
o Ensure that the appliance is in a safe condition, and then
reconnect it to the electric and gas supply.
o Open the oven door fully and ignite the oven burner. You should
set the oven to maximum temperature, then close the oven door
and leave the appliance for 10 – 15 minutes.
o Reduce the temperature to its minimum setting and remove the
thermostat control knob.
o DISCONNECT THE APPLIANCE FROM THE ELECTRICITY
SUPPLY.
o The bypass adjustment screw is located on the left hand side of
the valve body. Access can be made from the front of the
appliance and through the rear panel of the control panel. Turn
the screw clockwise to decrease the flow.
o Adjust the bypass setting until the correct flame picture is
achieved.
o Refit the control knob, then turn it to the Max position and then
back to Min several times, checking that the flame is maintained.
o Fully open and close the oven door several times and check that
the flame is maintained.
o Turn the appliance off and disconnect it from the gas supply.