o The oven must be installed by a qualified person, in accordance
with the current edition of the Gas Safety (Installation and Use)
Regulations and the relevant building/I.E.E. Regulations.
o Failure to install the appliance correctly could invalidate
Baumatic’s guarantee and lead to prosecution under the
regulations quoted above.
o In the UK, only GASSAFE registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.
Room ventilation requirements
o The room containing the oven should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
o If the room has a volume of less than 5m³, it will require an air
vent of 100cm² (effective area).
o If there are any other fuel burning appliances in the same room
the current edition of BS 5440: Part 2: should be consulted to
determine air vent requirements.
o Ensure that the room containing the oven is well ventilated, keep
natural ventilation holes.
o Prolonged intensive use of the appliance may call for additional
ventilation.
o This oven is not fitted with a device for discharging the products
of combustion. Ensure that the ventilation rules and regulations
are followed.
o Your oven must stand on a flat surface so that when it is in
position the oven is level. When in position check that the oven
is level by using a spirit level.
o Remember that the quantity of air necessary for combustion
must never be less than 2m³/h for each kW of power (see total
power in kW on the appliance rating plate).