User manual

Instructions for use, installation and connection
32
Nozzle chart
Type of gas,
pressure
Auxiliary burner Normal burner Large burner Triple burner
Standard Fast
Wobe number
max min max min max min max min max min
Natural gas H
Wo=45,7y
54,7 MJ/ m
3
,
Nominal heat
input (kW)
1 0,36 1 0,36 1,90 0,46 3 0,76 3,5 1,56
Natural gas E ,
Natural gas E+
Consumption (l/h)
95,21 34,4 95,21 34,4 180,9 43,8 285,64 72,4 333,2 148,5
Wo=40,9y
54,7 MJ/m
3
Nozzle mark
(1/100mm)
77 - 78 - 104 - 129 - 140
x
G20,
p=20mbar
Nozzle code
162081 162082 162083 162084 162085
Liquid gas 3+,
3B/P
Nominal heat
input (kW)
1 0,36 1 0,36 1,90 0,46 3 0,76 3,5 1,56
Wo=72,9y
87,3MJ/m
3
Consumption
(g/h)
71,7 26,2 71,7 26,2 138,1 33,4 215,0 55,3 254,5 113,4
G30
p=30 mbar
Nozzle mark
(1/100mm)
50 29/24 50 29/24 69 33/26 87 43/33 93 57/57
Nozzle code
162162 162162 162164 162165 162166
x Built-in regulation knobs are intended for liquefied gas. In case of natural gas (municipal
gas line) they need to be set according to the required gas flow (unscrew for maximum 1,5
turn from the tightened position).
Nozzle code for minimum varies with different manufacturers. First digit from the pair
represents IMIT, and the second one COPRECI.
Burner heating input is indicated according to the maximum caloric value of gas Hs.
Warning: this work may be performed only by qualified expert, authorized by the
gas distribution company or by the authorized service!