Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a CORGI registered
engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Remove the pan-stands, burners and flame
spreaders (A).
28
ow).
o Unscrew the injector (B) and replace it with
the stipulated injector for the new gas supply
(see table bel
* In reference conditions, gas temperature 15°C, atmospheric
pressure 1013.25 mbar
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.