Datasheet

www.baumer.com/motion
Inclination sensors
1
Subject to modication in technic and design. Errors and omissions excepted.1/2/2019
GIM500R with housing in aluminium
Features
Size 52 mm
MEMS capacitive measuring principle
ISO 13849 compliant rmware
E1 compliant design
Interface CANopen®, SAE J1939, Analog
Connection M12 and cable
Protection up to IP 69K
GIM500R - 1-dimensional
Technical data - mechanical design
Dimensions W x H x L 48 x 24 x 52 mm
Protection DIN EN 60529 IP 66, IP 67, IP 68, IP 69K
Material Housing: aluminium, coated
Corrosion protection IEC 60068-2-52 Salt mist
for ambient conditions C5-M
(CX) according to ISO 12944-2
Operating temperature -40...+85 °C
(see general information)
Resistance DIN EN 60068-2-6
Vibration 20 g, 60-2000 Hz
DIN EN 60068-2-27
Shock 200 g, 6 ms
Weight approx. 95 g
Connection Flange connector M12, 8-pin
Flange connector M12, 5-pin
Cable 1 m
Instruction Use in safety functions
exclusively based on Application
Note and MTTFd reliability
prediction (request separately).
1-dimensional, measuring range 0...360°
CANopen® / SAE J1939 / Analog
Optional
With integrated terminating resistor
Connection with DEUTSCH connector
Output signal with out-of-range diagnostics
Technical data - electrical ratings
Voltage supply 8...36 VDC
Reverse polarity protection Yes
Consumption w/o load ≤40mA(24VDC)
Initializing time ≤0.5safterpoweron
Interfaces CANopen®, SAE J1939, Analog
(4...20 mA / 0.5...4.5 V / 0...5 V /
0...10 V)
Load resistor ≥1kΩ/voltageoutput
≤800Ω/currentoutput
Measuring range 0...90°, 0...120°, 0...180°,
0...270°, 0...360°
Resolution 0.1 ° CANopen®
0.1 ° SAE J1939
12 Bit Analog
Accuracy (+25 °C) Typ. ±0.1°
Temperaturecoefcient 0.008 °/K
Repeatability ±0.1 ° (+25 °C)
Sensing rate 1600 Hz
Limit frequency 0.1...25 Hz, 2. order / low-pass
lter(Default:5Hz)
Interference immunity DIN EN 61000-6-2
ECE Reg. No. 10R04
ISO 7637-2
ISO 11452-2 / ISO 11452-5
Emitted interference DIN EN 61000-6-4
ECE Reg. No. 10R04
ISO 7637-2 / EN 55025
Programmable
parameters
Preset and offset
Filter
Diagnostic function Parameter error
Status indicator DUO-LED integrated in housing
Approval UL approval / E63076

Summary of content (8 pages)