User Manual

en_BA_O200_IO-Link_V1.docx 13/34 Baumer Electric AG
15.08.2018/ Frauenfeld, Switzerland
4.3.2.3 Hysteresis Alignment Mode (Only O200.G)
In case of axial detection tasks like stop trigger or level detection, an accurate switching distance is required.
To adapt the switching behavior and the hysteresis to the movement direction of the object, the alignment of
the hysteresis can be changed.
Only available for O200.G sensors.
Parameter name
Short Description
Rights
Unit / Allowed values
Hysteresis.SSC1
Alignment
Selection of the alignment modes
Available for SSC1.
Default: Right aligned
rw
- Left Aligned
- Center Aligned
- Right Aligned
4.3.2.3.1 Left Aligned
Left Aligned defines the hysteresis to be aligned towards the sensor / against the sensing direction.
When to apply?
- For an accurate switching distance in case the object is moving away from the sensor
Figure 12 Left Aligned, Single Point Mode
Figure 13 Left Aligned, Window Mode
4.3.2.3.2 Right Aligned
Right Aligned defines the hysteresis to be aligned away from the sensor / in sensing direction.
When to apply?
- For an accurate switching distance in case the object is moving towards the sensor.
o Example: Stop trigger application, usual detection tasks.
Figure 14 Right Aligned, Single Point Mode
Figure 15 Right Aligned, Window Mode