Operating Manual

Manual R600V.DAH5 Multi-object (EN)
Page 14 of 36 R600V.DAH5_multiobject_manual_1.1 (EN).docm
Last Update: 01 Jan 2021
2.2.3. Target area guidelines
Generally it is desirable that the sensor picks up only wanted objects. If objects in the back-
ground cannot be avoided the insertion of shields is recommended. As a rule of thumb a shield
angle larger than approx. the total opening angle (e.g. >10°) is recommended. Multi-path re-
flections may need to be considered.
Fig 9 Usage of shields to cover unwanted objects
Wanted objects should always be kept at a minimum distance of at least the specified blind
range. For best accuracy 400mm should be considered.
Fig 10 Separation of objects
Directionality
(opening angle)
Objects
Object separation
> blind range
Directionality
(Opening angle)
unwanted ob-
jects
wanted
objects
shields