Electrical Integration
The sensor can be used on direct vehicle power for 12VDC nominal voltage systems and
24VDC nominal voltage systems in the range +VS = 9VDC 32VDC). A centralized load
dump suppression (35V at 12VDC, and 58V at 24VDC respectively) is required. The product
shall not be used in the direct control and modification of the state of function of the machine.
Please refer to the data sheet for information regarding operation during the engine start
phase, and further technical details. Prior to electrical connection of the product the system
must be down and not live. Do not exceed permissible bending radius of the cable. The device
shall be appropriately protected by an external R/C or fuse. In an industrial environment the
device shall be protected by an external R/C or listed fuse, rated max. 100W/Vp or max. 5A
below 20VDC, and a UL class 2 power supply be used.
Tab 3 Connector Pin-Out
Connection type
Ampseal 16 4P (776536-1)
Mating connector
Ampseal 16 4P (776524-1)
Pin
Code
Description
1
+Vs
Positive Supply voltage (12VDC /
24VDC nominal)
2
CAN HI
CAN High
3
GND
Ground (supply voltage)
4
CAN LO
CAN Low
This product may be used on vehicle power fulfilling these requirements:
Tab 4 Vehicle Power Electrical Transients
Test pulse (ISO 7637-2, ISO 16750-2)
1
2a
2b
3a
3b
4
5b
Severity level
IV
III
IV
III
III
III
--
Functional status (12 VDC vehicle power)
C
A
C
A
A
C
A
Functional status (24 VDC vehicle power)
C
A
C
A
A
C
A
For test installations a cable with the order code 11213075 (ZCABL-ALL.AMP0300) may be
used.
ATTENTION
The product shall be used on machines with centralized load dump sup-
pression.
ATTENTION!
The product shall not be used in the direct control and modification
of the state of function of the machine.
ATTENTION!
The product shall not be operated during engine start phase.