User Manual
BA_FADK14IO-Link_V01-02-11_EN.doc  15/18  Baumer Electric AG 
04.12.2012    Frauenfeld, Switzerland
6  Overview of SPDUs 
6.1 
Table of General Information SPDUs
SPDU name 
SPDU index 
Number of Bytes 
Format 
Range of values 
R/W 
Comments 
General information on sensors     
Vendor Name  0X10  18  String  ASCII  R  “Baumer Electric AG“ for all sensors 
Product Name  0X12  22  String  ASCII  R  Corresponds  with  Baumer  article  descrip-
tion  
Product ID  0X13  8  String  ASCII  R  Corresponds with Baumer article number 
Serial Number  0X15  4  String  ASCII  R  Baumer P-Code 
Firmware Revision  0X17  8  String  ASCII  R  Baumer Firmware Revision 
Application  Specific 
Name 
0X18  8  -  -  R/W  8 Byte at customer disposal 
6.2  Table of Parameter SPDUs 
SPDU name 
SPDU index 
Number of Bytes 
Format 
Range of values 
R/W 
Comments 
Measuring range and switching points     
Switching points 
work 
0X40  4  Switching point A (HB, LB) 
Switching point B (HB, LB) 
500…4000  R/W  Distance information on switching points 
Switching points 
interim 
0X41  4  Switching point A (HB, LB) 
Switching point B (HB, LB) 
500…4000, 
65535 
R  Distance information on switching points  
Measuring range 
work 
0X42  4  Measuring range limit A (HB, LB) 
Measuring range limit B (HB, LB)
500…4000  R/W  Distance information on measuring range 
limits 
Measuring range 
interim 
0X43  4  Measuring range limit A (HB, LB) 
Measuring range limit B (HB, LB)
500…4000, 
65535 
R  Distance information on measuring range 
limits 
Sensor functions      
Average  0X50  1  -  0,1,2,4,8, 
16 
R/W  Number of measuring cycles across which 
an average is formed. 
Average value = 0 or 1: Average is 
switched off. 
Output function 
switching output 
0X62  1  0 = ON, if there is no valid signal 
within MB 
1 = Switching output defined by 
switching points 
2 = ON if signal falls below 
excess gain signal threshold 
0,1,2  R/W  Indicates what function is available on the 
output. 
Nominal value 
quality parameter 
0X65  1    1..8  R/W  Provided the internal quality parameter 
drops below this threshold, the switching 
output is set. 
Quality parameter  0X66  1    1..8 or 255  R   










