User Manual

BA_FADK14IO-Link_V01-02-11_EN.doc 15/18 Baumer Electric AG
04.12.2012 Frauenfeld, Switzerland
6 Overview of SPDUs
6.1
Table of General Information SPDUs
SPDU name
SPDU index
Number of Bytes
Format
Range of values
R/W
Comments
General information on sensors
Vendor Name 0X10 18 String ASCII R “Baumer Electric AG“ for all sensors
Product Name 0X12 22 String ASCII R Corresponds with Baumer article descrip-
tion
Product ID 0X13 8 String ASCII R Corresponds with Baumer article number
Serial Number 0X15 4 String ASCII R Baumer P-Code
Firmware Revision 0X17 8 String ASCII R Baumer Firmware Revision
Application Specific
Name
0X18 8 - - R/W 8 Byte at customer disposal
6.2 Table of Parameter SPDUs
SPDU name
SPDU index
Number of Bytes
Format
Range of values
R/W
Comments
Measuring range and switching points
Switching points
work
0X40 4 Switching point A (HB, LB)
Switching point B (HB, LB)
500…4000 R/W Distance information on switching points
Switching points
interim
0X41 4 Switching point A (HB, LB)
Switching point B (HB, LB)
500…4000,
65535
R Distance information on switching points
Measuring range
work
0X42 4 Measuring range limit A (HB, LB)
Measuring range limit B (HB, LB)
500…4000 R/W Distance information on measuring range
limits
Measuring range
interim
0X43 4 Measuring range limit A (HB, LB)
Measuring range limit B (HB, LB)
500…4000,
65535
R Distance information on measuring range
limits
Sensor functions
Average 0X50 1 - 0,1,2,4,8,
16
R/W Number of measuring cycles across which
an average is formed.
Average value = 0 or 1: Average is
switched off.
Output function
switching output
0X62 1 0 = ON, if there is no valid signal
within MB
1 = Switching output defined by
switching points
2 = ON if signal falls below
excess gain signal threshold
0,1,2 R/W Indicates what function is available on the
output.
Nominal value
quality parameter
0X65 1 1..8 R/W Provided the internal quality parameter
drops below this threshold, the switching
output is set.
Quality parameter 0X66 1 1..8 or 255 R