Instruction Manual

N 143
18 www.baumer.com
4.3.2. Read / write motor bit parameter „m“ (6Dh)
To make best use of the memory capacity, several parameters are compiled for packed transmission. Parame-
ter encoding is as follows:
Data1: 1 0 0 0 0 X 0 X
──┬── ─┬─ ─┬─
└─── KEY key assignment 0/1 (UP/DOWN)
└─────── DIRECT Motor direction of rotation 0/1 (UP/DOWN)
└──────────── reserved
└──────────────── ever 1
Data2: 1 0 0 X 0 X X X
──┬── ──┬──
└──── reserved
└──────── reserved
└──────────── TYP axis type 0/1 (radial/axial)
└──────────────── ever 1
Data3: 1 0 0 X 0 X X X
─┬─ ──┬──
└──── GROUP 0 7 (group1/group2/…/group8)
└──────── reserved
└─────────── reserved
└────────────── reserved
└──────────────── ever 1
Data4/5: 0 0 1 1 X X X X 0 0 1 1 X X X X
───────┬─────── ───────┬─────── reserved Master axis address for
TraBa (transport bar)
└──────── ADR LSB (value range 30h to 39h)
└─────────────────────────── ADR MSB (value range 30h to 39h)