Operator Control Panel Operation Instructions For Model(s): 2015 Pile Feed 2018 Pile Feed 2020 Pile Feed 2020 Continuous Feed TP10386 © Page 1 of 12
BAUMFOLDER 2000 Series “QUICK START” INSTRUCTIONS TURNING THE MAIN SWITCH ON When you turn on the Main Power Switch located on the side of the Control Box , you must let the Control automatically run a self-test. During the self-test DO NOT Press any buttons. Pressing of a button will cause an Error Message to appear in the Main Display. To CLEAR Message turn Power OFF at the Main Power Switch—WAIT 5 SECONDS, then turn Power back on. 1. Turn on Main Power Switch on left side of control enclosure.
. Then Press the GREEN Button to lower Pile Feed Table. The Table will lower and stop automatically in its lowest position. STARTING PRODUCTION WITH THE BAUM 2020 1. To START the Folder Drive, Press the GREEN Button on the Control Panel just ABOVE the symbol, this will Start the Folder Drive and the Pump will automatically come on. 2.
The Easy-Mode is used for folds that require half of the sheet length or less going into the foldplate. These folding applications normally operate with a 1 .0 Inch sheet gap. If you are folding half of the sheet length or more into the foldplate you must have a greater gap. TURN THE EASY-PARAMETER ON/OFF 1. Press the Machine Setup button found in the top row. 2. Press the Sheet Gap + or – Buttons until P20 appears in the sheet gap display. 3.
4. Look to the right hand end of the counter display. If an “ 1 “ appears in the display the Easy-Parameter is turned on. If an “ 0 “ is displayed, the EasyParameter is turned off, see Figure E1. To turn the Easy-Parameter on or off, Press the Plus (+) button for the batch time delay setup. Pressing this button changes the “ 1 “ to an “ 0 “ and back. This button is found at the far right side of the top row, see Figure E1. 5.
SELECT CONTINUOUS CYCLE MODE It is recommended to use the continuous cycle mode when the job requires more than ½ of the sheet length to go in the #1 fold plate or if the product has a window that will be sensed as the trailing edge of the sheet. The continuous cycle mode allows you to select the SHEET GAP, SHEET LENGTH and the SUCTION LENGTH. Pressing this button enables the selection of either the EASY mode or cYcL mode + + Pressing these buttons will toggle between the EASY mode or cYcL mode.
TO START FEEDING 1. Press the GREEN Button to START the Folder Drive and the Pump. 2. Press the GREEN Button ABOVE the symbol to START the Vacuum Solenoid. The Sucker Wheel will pull a sheet from the Feeder onto the Register. TO STOP FEEDING 1. Press the RED Button BELOW the symbol. This will turn the Vacuum Solenoid OFF. The Sucker Wheel will STOP pulling sheets—BUT the Folder Drive and the Pump will stay ON. NOTE: You can also STOP feeding by Pressing the RED PILE FEEDER STOP BUTTON.
EXAMPLE: Hold the MINUS Button, this will automatically count back to P00 (group P0). Now by Pressing the Button will take you to the next Parameter Group P10 – P20 - P30 – P40 – P50 – P60 2. Pressing and directly UNDER the left 3 digits of the Large 8 digit display, this will select the individual Parameters in a select group. EXAMPLE: Start with the first Group of Parameters, the 3 digit display reads P00.
TP10386 © Page 9 of 12
To get out of the Machine Parameter Settings Mode, Press displays will return to normal operations. again. The BATCH COUNTING SETUP To enter Batch Count Set-Up, Press 1. This will bring up 3 display functions on the Control Panel. First is the Small 3 digit display – this display must show ood If the display shows any other Mode, the Batch Counter will not function. To change, Press the or Buttons directly UNDER the 3 digit display to change this Mode of Operation.
the or Buttons directly UNDER the 2 digit display until the desired delay number is displayed. EXAMPLE: This is set-up for 10 pieces in a Batch with a 1.5 second delay between Batches. 3. To return back to RUN mode, Press Button and set either the Batch Size or Time Delay to Zero and the Folder will run continuously. STOP FEED In Batch Count Mode, you also can have the Feeder Set-Up for a Stop Feed Count.
and Stop Feeding. RESETTING THE TOTAL COUNTER To reset the Total Counter, Press Button illuminated. ; ensure the red LED is Press Button and HOLD DOWN for 3 SECONDS, The Large 8 digit display will begin to Count BACKWARDS from 5.4.3.2.1, then display CLEARED, the Counter is then ZERO.