You can rely on User Guide and Important Warranty Information Gold HE Range A Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.
Natural Gas Contents Potterton Gold Combi 24 HE A G.C.No 47 393 18 Potterton Gold Combi 28 HE A G.C.No 47 393 19 Potterton Gold Combi 33 HE A G.C.No 47 393 20 Section Page 1.0 Quick Reference Guide 3 2.0 Troubleshooting 4 3.0 Repressurising System 6 4.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Setting the Timer 10 8.0 Emergency 11 9.
1.0 Quick Reference Guide 3 2 1 12 11 PM 10 bar 4 11 Reset System Pressure Gauge Reset 12 Domestic Hot Water Temperature Control 1 Reset Central Heating Temperature Control 2 Display 3 ON/OFF/Reset Selector Switch 5 0 9 4 0 AM 8 7 7 3 8 1 9 Reset 5 2 10 4 Integral Timer Reset OFF Position Central Heating & Hot Water Domestic Hot Water Reset The boiler will not operate. Both Heating & Hot Water will operate. Hot Water will operate.
Boiler not working 2.0 Troubleshooting START Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). YES Is the ( ) or ( ) light on and the ( ) on ? YES Is the ON/OFF/Reset Select Switch in the ( ) position and the display lit ? Central Heating Indicator Domestic Hot Water Indicator NO If no gas, consult your supplier. NO Reset YES Display NO Check electricity to the boiler is switched on.
2.0 Troubleshooting Is the Integral Timer ON and calling for heat ? 2 1 3 12 YES Is the Room Thermostat (if fitted) set high enough ? YES 11 10 20 5 AM 8 7 7 8 PM 15 25 9 5 10 4 9 10 5 0 4 3 2 1 12 11 NO NO Turn Room Thermostat to maximum setting (typical example shown). Ensure timer is set for Central Heating ON (see Section 7.0 of these instructions - ‘Setting the Timer’) 15 20 25 5 10 CONTACT YOUR INSTALLER OR SERVICE ENGINEER.
3.0 Repressurising the System 3.1 1. The water pressure in the central heating system is indicated by the pressure gauge. 2 1 Fig. 1 3 2. With the system cold and the boiler not operating the pressure should be at least 0.5 bar. During operation the pressure should not exceed 2.5 bar, and will normally be between 1.0 and 2.0 (Fig. 1). 4 0 bar 2 Normal Pressure 1 Fig. 2 3 4 0 bar Requires Repressurising 2 1 Fig. 3 Central Heating System Pressure 3 3.
4.0 Clearances 450mm 5mm Min 5mm Min 200mm Min (300mm Min if using 80/125mm flueing system) 4.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty.
5.0 Care of the Boiler 5.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate in both modes. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 2.
6.0 Legislation 6.1 Installation, Commissioning, Service & Repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3.
7.0 Setting the Timer 10 7.1 8 The Electro-Mechanical Timer allows the central heating system to be set every 15 minutes. Constant Using the three position switch the timer will allow either constant operation, timed operation or central heating off. 7 Timed Move the switch button by sliding to the desired position. AM Off Three position switch (Fig. 6) 5 0 Constant (Top position): The heating will be on constantly irrespective of the position of the tappets.
8.
Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 731 1644.