Unit installation

Unscrew and remove the two screws
that secure the bottom of the fascia
sides to the convection box (See figure
47).
Remove the wiring loom connectors
from the left hand side of the gas valve.
Raise the fascia to allow the retaining
lugs at the top to clear the slots in the
convection box hood and then lift clear
(See figure 47). Be careful not trap the
wiring loom when lifting clear.
Dream
Remove the ash pan cover.
Remove the firefront casting.
Remove the wiring loom connectors
from the left hand side of the gas valve.
Remove the two screws securing the
bottom of the fascia to the sides of the
convection box.
Raise the fascia to allow the retaining lugs at the top
to clear the slots in the convection box hood and then
lift clear (See figure 43). Be careful not trap the wiring
loom when lifting clear.
17.2 To remove or clean the window unit.
Remove the fascia (See section 17.1).
Unscrew and remove the three spring-loaded
window-fixing screws and bushes from the base of the
window frame (See figure 48).
Gently swing the base of the window frame forward
while lifting the frame upward. The window should lift
clear of the fire. Put the window in a safe place away
from your immediate work area.
Any stains on the glass can be removed with a non-
abrasive cleaner such as a ceramic hob cleaner. Never
use abrasive cleaners. Clean the window carefully in accordance with the instructions
supplied with the cleaner.
Replace the window making sure that the seal around the frame is not damaged
or misplaced. Locate the channel at the top of the window over the top of the firebox
opening.
Refit the three spring-loaded screws and bushes. The wide part of the bushes
Page 41
© Baxi Heating U.K. Limited 2009.
Figure 48. Window fixing
Figure 47.
INSTALLER GUIDE