Unit installation

2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below:
Model
Efficiency % (Gross)
541 76
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
3. LIST OF AVAILABLE KITS
Description Part number
Spacer kit (5 inch) 0595121
Spacer kit (3 inch) 0595131
Timber frame Flue Clearance kit. 0583141
This kit includes:
1 off Insulation for rear of fire
1 off Flue clearance sleeve
1 off Drip collar
1 off External wall plate
Under no circumstances is the fire to be recessed into timber frame constructions. For
timber framed installations see section 8.
Page 9
© Baxi Heating U.K. Limited 2009.
Gas Conversion factor from net to gross efficiency
Natural Gas 0.901