Technical data

7.0 Site Requirements – page 13
Fig. 8
7.5 Ventilation of Compartments
1. Where the appliance is installed in a cupboard or
compartment, no air vents are required.
NOTE: The ventilation label on the front of the outer case
MUST NOT BE REMOVED when the appliance is
installed in a compartment or cupboard.
2. BS 5440: Part 2 Clause 4.2 refers to room sealed
appliances installed in compartments. The appliance
will run sufficiently cool without ventilation.
7.6 Gas Supply
1. The gas installation should be in accordance with
BS6891.
2. The connection to the appliance is a 22mm copper tail
located at the rear of the gas service cock (Fig. 8).
3. Ensure that the pipework from the meter to the
appliance is of adequate size. Do not use pipes of a
smaller diameter than the boiler gas connection
(22mm).
7.7 Electrical Supply
1. External wiring must be correctly earthed, polarised and
in accordance with current I.E.E. WIRING
REGULATIONS.
2. The mains supply is 230V ~ 50H
Z
fused at 3A.
NOTE: The method of connection to the electricity supply
must facilitate complete electrical isolation of the
appliance.
Connection may be via a fused double-pole isolator with
a contact separation of at least 3mm in all poles and
servicing the boiler and system controls only.