Technical data

Genesis Baxi Heating Ltd.
23
Making The Electrical Connections – page 23
Fitting a Room Thermostat
A 2-wire or 3-wire low voltage thermostat can be fitted to
the Genesis plug.
To fit a 2-wire thermostat, remove link, and wire the
thermostat switch between positions 1 & 2.
To fit a 3-wire thermostat, remove link, and wire the
thermostat switch between positions 1 & 2. The anticipator
should be wired to position 3, as this provides a continuous
24V supply.
FITTING AN EXTERNAL TIMER
The external timer must have voltage-free switch contacts.
The timer switch must be connected between positions 1 &
2.
FITTING A FROST THERMOSTAT
The frost thermostat must have voltage-free switch
contacts.
If room and frost Thermostats, and an external timer are to
be incorporated in the control system they should be wired
as shown.
Connect the multipin plug into the socket on the
power board.
Secure the incoming cable/s with the cable damp and
replace the cover.