Thermistors
The procedure is the same for both domestic hot water and
central heating thermistors.
Remove the electrical connection from the thermistor.
Remove the spring clip retaining it to the manifold.
Withdraw the thermistor.
Reassemble in reverse order.
Safety Thermostat
Remove the electrical connections from the sensor.
Remove the retaining clip from the flow pipe.
Remove the sensor from the clip.
Apply heat transfer paste and reassemble in reverse order.