Quick Start Manual

www.baxi.co.uk/avanta
13
Unit of
Measure
Baxi Avanta
Plus System 18
Baxi Avanta
Plus System 24
Baxi Avanta
Plus System 30
Part number (boiler only) 7604562 7604563 7604564
Standard Horizontal Flue 720698701 720698701 720698701
Controls
Concealed User Controls No No No
On/Off Switch with Reset Yes Yes Yes
User Adjustable CH Temperature Yes Yes Yes
Gas
Gas Supply Pipe Size mm 22 22 22
Natural Gas Yes Yes Yes
LPG (Butane/Propane) Optional Optional Optional
Gas Consumption Natural Gas (LPG) m3/hr 1.9(0.7) 2.3(0.85) 3.2(1.2)
Heat Output Central Heating (minimum/maximum) kW 5.8 / 18.3 5.8 / 22 6.1 / 30
SEDBUK (2005) Rating Band A A A
2C?QML?J$DAGCLAW-&+/& % 90.3 90.3 90.4
2C?QML?J$DAGCLAW-&+/& % 88.8 88.9 88.9
N0x Class 555
N0x Levels mg/kWhr 37 37 37
Electrical
Electrical Supply Volts / Hz 230 / 50 235 / 50 230 / 50
Permanent Live Required Yes Yes Yes
Fitted Electrical Cable Yes Yes Yes
Power Consumption Watts 115 115 115
External Fuse Rating Amps 3 3 3
(LEPCQQ/PMRCARGML1?RGLEUGRFMSRKCAF?LGA?JRGKCPRRCB IP X4D X4D X4D
24-hour Pump Exercise Yes Yes Yes
Integral Boiler Only Frost Thermostat Yes Yes Yes
Mechanical and Hydraulic
Mounting plate including taps Yes Yes Yes
CH Flow and Return Pipe Size mm 22 22 22
Condensate Discharge Pipe Size Inch 3/4 3/4 3/4
Minimum Operating Water Pressure bar 1 1 1
Safety Discharge Pressure bar 3 3 3
Integral Expansion Vessel Capacity litres 8 8 8
Filling Loop Included Yes Yes Yes
Concentric Flue System
Standard Telescopic Horizontal Flue Kit Length mm 315 - 500 315 - 500 315 - 500
Max Equiv Length Horizontal/Vertical 60/100 / (80/125) m 6 (29) 6 (29) 6 (29)
Equivalent Length per 135’ Bend (60/100) & (80/125) m 0.5 0.5 0.5
Equivalent Length per 93’ Bend (60/100) & (80/125) m 1 1 1
Weights
Max Installation Lift Weight kg 29.0 29.0 32.0
2B@EKF@>IPMB@F@>QFLKP
Baxi Avanta Plus System