Quick Start Manual

23
www.baxi.co.uk/avanta
Terminal Position with Minimum Distance (mm)
A
1
Directly below an opening, air brick, opening
cte ,swodniw
B
1
Above an opening, air brick, opening window etc 300
C
1
Horizontally to an opening, air brick, opening window etc 300
D
2
52epip niard ro sepip lios ,srettug woleB
E
2
52evae woleB
F
2
52oor trop rac ro seinoclab woleB
G
2
52epip lios ro epip niard lacitrev a morF
H
2
52renroc lanretxe ro lanretni na morF
003level ynoclab ro foor ,dnuorg evobAI
J
From a surface or boundary line facing a terminal
K From a terminal facing a terminal (Horizontal flue)
K
From a terminal facing a terminal (Vertical flue)
L From an opening in carport (e.g. door, window)
gnillewd eht otni
1.
In addition, the terminal should be no nearer than 150mm to an
opening in the building fabric formed for the purpose of accommodating a
built-in element such as a window frame.
2.
Only ONE 25mm clearance is allowed per installation. If one of the
dimensions D, E, F, G or H is 25mm then the remainder MUSTbe as
B.S.5440-1.
M Vertically from a terminal on the same wall 1500
N Horizontally from a terminal on the same wall 300
) 300ylno lacitrev( eulf ot llaw tnecajda morFR
S From an adjacent opening window (vertical only)
T Adjacent to windows or openings on pitched and flat roofs
U Below windows or openings on pitched roofs
300
1200
600
1200
s
s
f
1000
600
2000
600
N
I
I
G
F
M
I
A
A
F
H
J,K
D
E
H
C
R
A
I
J,K
I
L
S
B
T
U
Likely flue positions requiring
a flue terminal guard
Te r m i n al
Assembly
Top View Rear Flue
Property Boundary Line
300mm min
Opening Window
or Door
150mm
min.
Plume
Displacement Kit
Air Inlet
IMPORTANT: (DRRGLE?
Plume Displacement Flue
Kit, the air inlet must be a
minimum of 150mm from any
opening windows or doors
NOTE: The distance from a fanned draught
appliance terminal installed parallel to a
boundary may not be less than 300mm in
accordance with the diagram.
Flue options