Technical data

Brazilia F5, F5S & F8S Baxi Heating Ltd.
5
2.0 Technical Data – Page 5
F 5 & F 5S Natural Gas F 8S Natural Gas
Category of Appliance 1
2H
The appliance is set for Gas Type G20 at 20mbar.
Category of Appliance 1
2H
The appliance is set for Gas Type G20 at 20mbar.
Heat Input (gross) High Med Low Heat Input (gross) High Med Low
kW 2.05 1.41 0.86 kW 3.06 2.21 1.27
Btu/h 7,000 4,800 3,000 Btu/h 10,440 7,540 4,333
Heat Output (gross) High Med Low Heat Output (gross) High Med Low
kW 1.5 0.98 0.57 kW 2.26 1.48 0.80
Btu/h 5,100 3,350 1,950 Btu/h 7,700 5,050 2,730
Inlet Setting Pressure Cold Inlet Setting Pressure Cold
mbar 19.7 ± 0.75 mbar 19.25 ± 0.75
in wg 7.9 ± 0.3 in wg 7.7± 0.3
Injector Size CO
2
Injector Size CO
1
Nox Class 3 Nox Class 2
Gas Rate
on HIGH
0.195 m
3
/h (6.89 ft
3
/h)
Gas Rate
on HIGH
0.29 m
3
/h (10.28 ft
3
/h)
Gas Connection R ¼ (¼ BSP external) Gas Connection R ¼ (¼ BSP external)
Ignition Piezo Spark Ignition Piezo Spark
Packed Weight 5 5S Packed Weight 8S
18kg 18.4kg 24.4 kg
(39.7 Ibs) (40.6 Ibs) (54 Ibs)
Dimensions 5 5S Dimensions 8S
Height 394mm 394mm Height 430mm
Width 426mm 450mm Width 51 6mm
Depth 126mm 128mm Depth 152mm
(from the wall) (from the wall)
Controls Rotary gas tap allowing
manual adjustment between
low, medium and high
output.
Flame failure device.
Controls Rotary gas tap allowing
manual adjustment between
low, medium and high
output.
Flame failure device.
Thermocouple
Output
8-l3mv Thermocouple
Output
8-l3mv
Heat Exchanger Cast Iron Heat Exchanger Cast Iron
B.S. Codes of Practice
STANDARD SCOPE
B.S. 68g1 Gas Installation.
B.S. 5440: Pt. 1 Flues.
B.S. 5871 Pt.1 Installation of fires, convector heaters