Operating instructions
5.0 Safety Devices
8
Fig. 4
Flow Temperature
Control
Burner ON
Light - Green
Mains ON
Light - Green
Low
High
ON
Reset
Fault
Light - Red
Reset
Button
5.1 Operation of Safety Devices
1. Your Baxi System 100 HE Plus is fitted with safety
devices which shut down the appliance if:
a) the system overheats.
b) the condensate drain is blocked.
c) there is no gas to the boiler.
2. The fault light - red ( ) will be either flashing or
permanently illuminated and the boiler will need resetting
(Fig. 4).
NOTE: In the case of persistent operation of the
devices, turn off the boiler and consult your service
engineer as an appliance or system fault is indicated.
5.2 Resetting (Fig. 4)
1. Check that the gas, water and electricity supplies to the
appliance have not been inadvertently turned off.
2. Check the condensate drain outlet has not been
blocked.
WARNING: The condensate outlet must not
be blocked or modified.
3. Allow the boiler to cool if hot.
4. Hinge down the lower door panel.
5. Press the Reset Button.
Lower Door Panel