Technical data

7.0 Site Requirements
19
7.8 Flue Dimensions
See Section 2.2. The standard horizontal flue kit allows for
flue lengths between 270mm (10
5
/
8
”) and 800mm (32”)
from elbow to terminal (Fig. 17).
The maximum permissible equivalent flue length is: 4
metres (Fig. 18).
NOTE: Each additional 45° of flue bend will account
for an equivalent flue length of 0.5m.
eg. 45° = 0.5m, 90° = 2 x 45° = 1m etc.
7.9 Terminal Guard (Fig. 19)
1. When codes of practice dictate the use of terminal
guards, they can be obtained from most Plumbers’ and
Builders’ Merchants.
2. There must be a clearance of at least 50mm between any
part of the terminal and the guard.
3. When ordering a terminal guard, quote the appliance
model number.
4. The flue terminal guard should be positioned centrally
over the terminal and fixed as illustrated.
7.10 Vertical Flue
1. Only a flue approved with the Baxi System 100 HE Plus
can be used.
2. For information on vertical flues consult the Baxi Flue
Guide Brochure or Notes for Guidance supplied with the
vertical flue pack.
Fig. 17
Fig. 18
Pictorial examples of flue runs where EQUIVALENT flue length equals 4m
Fig. 19
270mm 800mm
0.5m
1m
0.5m
0.5m