User’s Operating Instructions & Important Warranty Information Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.
Natural Gas Contents Baxi Combi 133 HE Plus G.C.No 47 075 14 Baxi Combi 100 HE Plus G.C.No 47 075 15 Baxi Combi 80 HE Plus G.C.No 47 075 16 Baxi is one of the leading manufacturers of domestic heating products in the UK. Our first priority is to give a high quality service to our customers. Quality is designed into every Baxi product products which fulfil the demands and needs of customers, offering choice, efficiency and reliability.
1.0 Quick Reference Guide Key to Controls ON High Low Low High Domestic Hot Water (Green Light) This indicates that the Burner has fired up and heating your water. Flame Failure (Red Light) If Flame Failure Light is ON press the Reset Button. If Flame Failure occurs frequently consult your Installer. Burner On (Green Light) This indicates that the Burner has fired up and is heating your system. Mains On (Green Light) This indicates that there is electricity to the Boiler.
2.0 Troubleshooting Boiler not working START YES Is there electricity to the boiler ? (Green Mains ON Light lit). YES Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). NO Hig Is the Green Burner ON Light illuminated ? NO h Hig Low h Low Rese t If no gas, consult your supplier. Reset Burner ON Light (Green) Mains ON Light (Green) ON ON Hig h Hig Low h Low YES NO Check electrical supply to boiler is switched on.
2.
3.0 Repressurising System 3.1 1. The normal operating water pressure is in the green area between 1 and 2.5 bar (Fig. 1). If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your installer. normal pressure 1 2 3 0 Central Heating System Pressure 2. It may be necessary to repressurise the system occasionally (Fig. 2). A filling device (the ‘filling loop’) will be fitted on the system.
4.0 Clearances 490mm 5mm Min 5mm Min 200mm 4.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations.
5.0 Care of the Boiler 5.1 Cleaning the Outercase 1. The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precautions 1. The boiler incorporates an integral frost protection feature that will operate in both modes. If the boiler temperature falls below 4 °C, the boiler will fire until a temperature of 15 °C is reached. 2.
6.0 Legislation 6.1 Installation, Commissioning, Service & Repair 1. This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3.
7.0 Emergency Warning ! If you smell gas Turn off the gas supply at the meter and call your gas supplier immediately. It is possible to isolate the boiler and at the isolating valve (Fig. 7). Transco operate a 24 hour emergency service and the telephone number will be listed in your telephone directory. Faulty boiler Tap If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person.
Notes © Baxi Heating UK Limited 2005 11
Please complete the boxes below 8.0 Warranty & Service Serial Number Standard Warranty Terms & Conditions 12 Months Free Warranty - register today To receive your 12 months free warranty please complete the form supplied with the boiler or simply call heateam, the service division of Baxi Heating UK Limited on 08706 000 653.