User’s Operating Instructions Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
Natural Gas Baxi Combi 133 HE Plus G.C.No 47 075 14 Baxi Combi 100 HE Plus G.C.No 47 075 15 Baxi Combi 80 HE Plus G.C.No 47 075 16 Baxi is one of the leading manufacturers of domestic heating products in the UK. Our first priority is to give a high quality service to our customers. Quality is designed into every Baxi product products which fulfil the demands and needs of customers, offering choice, efficiency and reliability.
1.0 Introduction 1.1 Introduction 1. Your Baxi Combi 133 - 100 - 80 HE Plus are gas fired, room sealed, powered flue condensing combination boilers, providing central heating for your home and mains fed domestic hot water. It is fully automatic and does not have a pilot light. Boiler frost protection and pump protection are an integral part of the appliance. 2. Due to the high efficiency and the resulting low flue gas temperature a white plume of condensate will be emitted from the flue outlet terminal.
2.0 Operating the Boiler 2.1 Temperature Control Central Heating The boiler will automatically achieve the optimum flow temperature for maximum comfort and efficiency. 1. However, in the case of the elderly, infirm or very young, a lower radiator surface temperature may be desirable. If so, the central heating flow temperature can be adjusted between approx 55 °C minimum and approx 82 °C maximum by turning the Central Heating Maximum Radiator Temperature Control Knob (Fig. 2). 2.
3.0 Care of the Boiler 3.1 Central Heating System Pressure 1. The water pressure in the central heating system is indicated by the pressure gauge. 2. The normal operating pressure is in the range between 1 and 2·5 bar. 3. A pressure of 3 bar or greater indicates a fault The safety pressure relief valve will operate at a pressure of 3 bar and very hot water or steam will be discharged through the pipe on the right hand side of the boiler, out of the property and usually into a nearby drain.
3.0 Care of the Boiler 3.5 Guarantee 1. Your Baxi Combi HE Plus Range is designed and produced to meet all the relevant Standards. 2. Baxi provide a 12 month guarantee on the boiler. The guarantee operates from the date installation is completed for the customer who is the original user. 3. To maximise the benefit from our guarantee we urge you to return the reply-paid guarantee registration. 4. This does not in any way prejudice your rights at Common Law.
4.0 Safety Devices 4.1 Operation of Safety Devices 1. Your Baxi Combi HE Plus Range is fitted with safety devices which shut down the appliance if: a) the system overheats. b) the condensate drain is blocked. c) there is no gas to the boiler. 2. The flame failure light ( ) will be either flashing or permanently illuminated and the boiler will need resetting (Fig. 4).
5.0 Clearances 490mm 5mm Min 5mm Min 5.1 Clearances around the Boiler 1. The minimum clear spaces needed around the boiler measured from the casing are as follows: 200mm Top Bottom Both sides Front 850mm - 200mm 200mm 5mm 500mm 5mm (For Servicing) (In Operation) 2. These areas must not be obstructed in any way. Blocking the clearance spaces may result in the boiler overheating and damage may occur. 3.
6.0 Fault Finding/Emergency 6.1 Check List 1. If a fault develops, or is suspected, call a Competent Person as soon as possible. 2. Go through the following check list before you make contact. a) c) d) e) f) g) h) i) 6.2 Is the electricity supply on ? Is the Red “Flame Failure’ light illuminated ? If the boiler fails to light or the boiler is running and the gas is turned off, the LED will start to flash red.
7.0 Legislation 7.1 IMPORTANT - Installation, Commissioning, Service & Repair This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations.
8.
When contacting Baxi Potterton please have the following information to hand: Appliance Name Model Number Serial Number A label giving these details is situated on the rear of the lower door panel attached to the users operating instruction label. Users Operating Instruction Label Lower Door Panel Label B A X I P OTTERTO N A Trading Division of Baxi Heating UK Ltd Brownedge Road Bamber Bridge Preston Lancashire PR5 6UP After Sales Service 08706 096 096 Technical Enquiries 08706 049 049 Website www.baxi.