The Collector panel temperature sensor should be
installed in the sensor pocket nearest to the collector
array flow. It should be secured in pocket by inserting
through the rubber gland provided.All materials used for
installing temperature sensors (sensor element, conducting
compound, cables, sealing and insulating materials) must
be suitably temperature resistant (up to 250°C).
NOTE:“On-roof” type panel shown.The “In-roof” type
panel has connections on the top edge of the collector
(see Fig. 2.2) and the sensor pocket is located behind the
left hand connection.
8.0 Installation of collector panel sensor
Fig. 9