USER GUIDE Solar Collectors Please read these instructions before installing or commissioning. This Solar Thermal Domestic Hot Water System should only be installed by a competent person.
1.0 1.1 Installation and Handover Information When your Solar domestic water heating system was installed the installer should have fully commissioned the system and left it in working order. Following this they should have explained the system, its function and control including: Heating by solar Explained how the cylinder is heated when there is sufficient solar energy.
2.0 2.1 Baxi Solarflo Description Description Your Solar system consists of several component parts that work together to heat your domestic hot water supply either from the power of the sun, by conventional means (by a boiler or electric immersion heaters) or combination of both. This combination is required because the sun’s energy is not uniformly received throughout the year (some 70% of the UK’s annual radiation is received over the period April to September).
3.0 3.1 System Operation Operating Settings Generally the operating settings of your domestic solar hot water heating system will have been set up by your installer. For the system to operate correctly and efficiently these settings should not be altered. Section 4 details the user controls which your installer should familiarise you with during commissioning the system.
Diagram of Menu Options 4.0 Main Menu 4.1 User Controls Main Menu To make the operation of the controller clear, operating and display functions are divided into 4 main menus. 1 Display Screen Info Indication of current measured values. Indication of system condition. Indication of error messages. Indication of operating hours and energy productivity (if installed). Programming Changes to programmable values (parameters). Manual operation This menu is for the installation engineer only.
Press or to scroll 4.0 User Controls up or down to the required sub function. The icon will flash, press to select the function. Reset by pressing or for ok? appears, press disappears. to confirm and Menu “Info” In this menu mode all measured values and operating states are shown. increase/decrease values. Press and 4.
Press or 4.0 to scroll User Controls up or down to the required sub function. The icon will flash, press to 4.3 select the function. Reset by pressing or for increase/decrease values. Press and ok? appears, press disappears. to confirm and ok? Menu “Programming” All adjustable parameters can be checked in this menu and, if necessary, changed. The default factory setting will usually give efficient and problem free operation.
4.
5.0 Important Notes If the system pressure falls to zero, switch off the power supply to the Solar Controller and contact a qualified solar heating engineer. Familiarise yourself with the controls and instructions supplied with the Solar Cylinder and follow manufacturer’s instructions in the event of a cylinder fault. The pipework between the solar collector(s) and the solar cylinder can be very hot. These pipes should have been insulated by the installer. This is high temperature insulation.
6.0 Servicing and Maintenance To ensure the continued safe and efficient operation of your Solar Water Heating System, it should regularly be checked and maintained by a qualified engineer. It is recommended that checks be carried out on an annual basis in accordance with the maintenance requirements detailed in the 2nd Fix Manual. Additionally the concentration of the solar thermal transfer fluid should be checked and if necessary topped up or replaced every 2 years.
7.
All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. MULTIFIT A Registered Trademark of Baxi Heating UK Ltd (3879156), Brooks House, Coventry Road, Warwick. CV34 4LL Technical Enquiries 0844 8711555 Website www.baxiheating.co.