Owner's Manual

4.0 User Controls
6
© Baxi Heating UK Ltd 2011
4.2 Menu “Info”
In this menu mode all measured values and operating states
are shown.
If the values are marked as “reset possible”, they may be reset
in the following way:
Choose the value with buttons and
Reset value by means of the button
Message “OK?” confirm with = no or = yes
Indication Description Reset possible
75ºC Indication of current collector temperature no
min. 12ºC Indication of minimum collector temperature yes
Re-settable to current temperature
max. 105ºC Indication of maximum collector temperature yes
Re-settable to current temperature
52ºC Indication of current temperature storage tank (lower) no
min. 40ºC Indication of minimum temperature storage tank (lower) yes
Re-settable to current temperature
max. 65ºC Frost protection or common measuring point yes
25ºC Indication of universal temperature measuring points (T3) no
55ºC Indication of current temperature storage tank thermostat no
60ºC Indication of current temperature collector return no
60ºC Indicates Auxiliary Heating Coil Temperature no
T6
1234 h Operating hours for charging storage tank Yes
Resettable to 0 h
927 kWh Energy productivity for storage tank (where applicable) Yes
Resettable to 0 kWh
Press or to scroll
up or down to the required sub function.
The icon will flash, press to
select the function. Reset by pressing
or for
increase/decrease values. Press
and appears,
press to confirm and
disappears.
ok?
ok?
Example of Screen Display