Owner's Manual
4.0 User Controls
7
© Baxi Heating UK Ltd 2011
4.3 Menu “Programming”
All adjustable parameters can be checked in this menu and, if
necessary, changed. The default factory setting will usually give
efficient and problem free operation. However Baxi recommend
the following parameters marked * must be left at the default
settings. Any change to the Baxi recommended settings will
invalidate the warranty.
Indication Description Value range Defaults
max Storage 1/2: 15..65ºC 65ºC *
65ºC Maximum temperature
dT max Storage 1/2: Hysteresis (dT on) * 3..40 K 7 K
7 K
dT min Storage 1/2: Hysteresis (dT off) * 2..35 K 3 K
3 K
min Setting the speed control of the pump 30%..100% 100%
100 100% = speed control off
min Temperature start for the function 20..90ºC 40ºC
40ºC heating
dT Hysteresis heating 1..30K 10K
10K
2
Press or to scroll
up or down to the required sub function.
The icon will flash, press to
select the function. Reset by pressing
or for
increase/decrease values. Press
and appears,
press to confirm and
disappears.
ok?
ok?
* Temperature lag between switch on and switch off