Quick Start Manual

© Baxi Heating UK Ltd 2009
4.0 Site Requirements
12
4.5 Ventilation of Compartments
1. Where the appliance is installed in a cupboard or
compartment, no air vents are required. The Solo 3
PFL will run sufficiently cool without ventilation.
NOTE: The ventilation label on the front of the
outer case MUST NOT BE REMOVED when the
appliance is installed in a compartment or
cupboard.
2. B.S. 5440 refers to room sealed appliances installed
in compartments.
4.6 Gas Supply (Fig. 14)
1. The gas installation should be in accordance with the
relevant standards. In GB this is BS 6891. In IE this is
the current edition of I.S. 813 “Domestic Gas
Installations”.
2. The connection of the appliance is a RC
1
/
2
(
1
/
2
in
BSPT internal) located at the rear of the gas cock.
3. Ensure that the pipework from the meter to the
appliance is of adequate size. Do not use pipes of a
smaller diameter than the appliance gas connection.
4.7 Electrical Supply
External wiring must be correctly earthed, polarized
and in accordance with the relevant regulations/rules.
In GB this is the current I.E.E. Wiring Regulations. In IE
reference should be made to the current edition of
the ETCI rules.
The mains supply is 230V ~ 50Hz fused at 5A.
NOTE: The method of connection to the
electricity supply must facilitate complete electrical
isolation of the appliance.
Connection may be made via a fused double-pole
isolator with a contact separation of a least 3mm in all
poles and serving the appliance and system controls
only.
Fig. 14