ASSEMBLING THE FIXTURE (Fig.2, See the Page 2)
1. Attach the column(I) to the top screw hole of lamp holder(K) and tight it until snug.
Place the candle sleeve(L) insert to the lamp holder.
2. Note: attach the small arm to the side hole of the big ring, aligning the arm’s screw
hole with the ring’s hole, lock it securely with the screws. The assembled is “M”.
3. Raise the bell glass(N) insert the big ring(M), fasten the ring’s arm, hooked the end
small ring of pipe(J), the pipe(J) other end small ring hanging the column’s hooks.
4. Install the light bulbsNot includedin accordance with the fixture specifications.
NOTE: DO NOT EXCEED THE SPECIFIED WATTAGE!
HANGING THE FIXTURE (Fig.1)
1. Shut off the power at the circuit breaker and remove old fixture from ceiling, including
the old single bar. Carefully unpack new fixture and lay all the parts on a clear surface.
2. Thread nipple (C) into loop (F) until snug.
3. Thread other end of nipple (C) with loop attached into single bar (D) until snug.
4. Place lock washer (B) over end of nipple protruding through single bar and thread hex
nut (A) onto nipple until tight.
5. Take this single bar assembly and mount to ceiling junction box with junction box
screws (E). Tighten screws securely with screwdriver.
6. Using proper chain pliers to open one end link of the chain provided and connect to the
fixture loop. Close the link.
7. By measuring, determine correct number of links needed for proper hanging height.
Using proper chain pliers disconnect and discard remaining chain.
8. Lace the fixture wires through the chain.
9. Slip loop collar (H) over the chain, then do the same with the canopy (G).
10. Open the other end link of the chain and hang the fixture on the loop at the ceiling .
Close the link.
11. Feed the fixture wires through the loop (F) and nipple (C) and pull until taut.
CONNECTING THE WIRES (Fig.3)
1. Take the black wire from the ceiling junction box and the smooth wire leg from the
fixture and twist bare ends together. Twist wire connector onto end of wire until snug.
2. Repeat same process with white junction box wire and ribbed wire leg of fixture wire.
NOTE: Twist wires together in the same direction you twist the wire connector onto
wires.
3. If your junction box has a grounding wire (green or bare copper), attach this wire and
the bare copper wire from the fixture together as step 1. If junction box has no ground
wire, attach the bare copper fixture wire to the green ground screw on the crossbar.
4. Tuck these wire connections neatly into the ceiling outlet box and then raise the
canopy (G) all the way to the ceiling. Raise the loop (H) and thread onto ceiling loop
protruding through canopy.
Your installation is now complete. Return power to the junction box and test the
fixture.
D
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black(Hot)
FIXTURE
WIRES
White or
Ribbed
FIXTURE
WIRES
Bare
Copper
(Ground)
HOUSE
WIRES
White
(Neutral)
HOUSE
WIRES
Green or Bare
Copper(Ground)