Installation guide

4-13Remote Annex 4000 Hardware Installation Guide
Chapter 4 Troubleshooting Procedures
Table 4-5. Errors from Last ERPC Layer Invocation
Table 4-6. Errors from Last Read Request
Error Description
H/W errors The Remote Annex 4000 sensed a hardware error during
message transmission or reception. This error indicates a
fault with the Remote Annex 4000, the transceiver cable,
or the transceiver. Use the net command to isolate the
problem (see
net on page 3-22).
Msgs from
wrong host
The Remote Annex 4000 received a message from an
incorrect host. This indicates that the Remote Annex
4000 received, and ignored, an unsolicited packet.
Rsp T/O’s The Remote Annex 4000 never received a correctly
formatted response from the correct host, or any
response from any load server hosts.
Msgs of
wrong type
The correct host sent a message to the Remote Annex
4000, but the message was not a correctly formatted
response to the transmitted request.
Error Description
Msgs with wrong
size
The correct host responded to the Read Request,
but the data size is incorrect.
ERPC layer errors See Table 4-5.
Aborts rx’d The host’s BFS transmitted an abort in response to
the Remote Annex 4000’s Read Request. Run
erpcd –D on the host to obtain more information.