Installation guide

1-13Remote Annex 4000 Hardware Installation Guide
Chapter 1 Introduction
Mode Jumper
The Mode Jumper is used to configure the Remote Annex 4000
properly to ensure compatibility with the operational image.
The
Mode Jumper setting is checked by the PROMs only at power-up or
reset time.
The jumper must be installed when running images prior
to Release 9.3. When running Release 9.3 or newer images,
this jumper should be removed.
Network Interface
Connectors
The Remote Annex 4000 comes with an integrated 10Base2, 10Base5,
and 10BaseT auto sense Ethernet connector. Connect to your LAN
using one of the following:
10Base2 (Thin Ethernet) Ethernet port with a BNC connector.
10Base5 (Thick Ethernet) Ethernet transceiver port with a
DB15 connector.
10BaseT (Twisted Pair Ethernet) Ethernet port with an RJ-45
connector.
A Link Indicator LED is provided. This LED is green when an active
10BaseT segment is attached.
Connect only one interface at a time.
The Remote Annex must be reset when changing network
interface connections.