Operating instructions
ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE
Fire Detection - Addressable
The Protec Algo-Tec™ 6300 Interactive Digital 
Addressable System unwrapped:
The Protec Algo-Tec
TM
 6000 protocol developed by 
Protec’s in-house Research and Development team is 
utilised by the Protec Algo-Tec
TM 
6300 interactive digital 
addressable fire control systems. Immunity to false 
alarms, more responsive fire detection, and ease of use 
has all been achieved to develop one of the most reliable 
systems available.
Protec Algo-Tec™ 6300
The name Algo-Tec
TM
 is a derivative of Protec algorithms. 
Algorithms are logical mathematical procedures for 
solving problems. Protec have developed fire detection 
algorithms coupled with fuzzy logic specifically designed 
to reduce unwanted fire alarms and to enhance the 
sensitivity of the system to true fire phenomenon. The 
Algo-Tec
TM
 algorithms are exclusively utilised by the 
Protec Algo-Tec
TM
 6400 and 6300 Interactive Digital 
Addressable Fire Control Systems.
Interactive
Algo-Tec
TM
 evaluates the data of each fire sensor 
and is able to learn from the information received. 
This may simply be to recognise that a sensor is 
becoming contaminated or in a dirty environment 
and to automatically increase the alarm threshold 
to compensate for the background levels (Threshold 
Compensation).
More complex Algo-Tec
TM
 functions include the ability 
to discriminate between certain fire and non-fire 
conditions, filtering out certain environmental stimuli, 
and increasing the sensitivity of a sensor when an 
increase in temperature is detected.
The net effect of the interaction between the sensors 
and the Algo-Tec
TM
 decision making is enhanced 
performance, through immunity to false alarms and more 
responsive fire detection.
Digital Addressable
The data communication between the sensors and the 
control equipment is Digital. 
The Algo-Tec
TM
protocol utilised by the 6000 system 
enables high levels of data to be transferred, providing 
far more detailed information than was previously 
achievable with analogue addressable systems. It should 
however be noted that many analogue addressable 
systems use digital communication but do not transfer 
the high levels of data associated with the Algo-Tec
TM
protocol. Speed, stability, excellent EMC and security all 
serve to enhance the Algo-Tec
TM
 Digital signalling. Why 
go analogue addressable when you can now choose 
Algo-Tec
TM
Digital Addressable.
Protec Fire Detection plc
Protec Algo-Tec
TM
 6300
INTERACTIVE DIGITAL ADDRESSABLE
FIRE CONTROL SYSTEM
Protec
Protec Fire Detection plc
NOTE: The above examples give an indication of system reaction to intermittent contaminants and 
typical fire sources in a correctly designed BS5839 system . They by no means detail the full complexity 
of the systems decision making algorithms. Examples are for 6000PLUS/OPHT. 
Clean Mode (Extra High Performance)
Day/Night Mode
Steam From Bathroom
DISCRIMINATING
ALGORITHM
Aerosols in Bedroom
DISCRIMINATING
ALGORITHM
Bedroom Mode
Office Mode (High Performance)
Cigarette Smoke
DISCRIMINATING
ALGORITHM
ALARM
Bin Fire
ALARM
Printer Paper Fire 
Factory Loading Bay
Offices
Night Mode:
Clean mode (Extra high performance) 
Night Mode:
Smoke & Heat detection 
Factory Loading Bay
Offices
Day Mode:
Office mode (high performance) 
Day Mode:
Heat detection only (6000
PLUS/OPHT) 
ALARM
Computer Fire
ALARM
Computer Room Fire 
ALARM
Chemical Fire
CAUTION
Algo-Tec™ 6000PLUS
  Interactive Decision Making Algorithms - Typical Applications
ALARM
Smoldering Fire