Copyright 1998 by Bay Technical Associates, Inc. BayTech is a registered trademark of Bay Technical Associates, Inc. IBM, IBM PC, IBM PC/AT, IBM PC/XT are products and registered trademarks of International Business Machines Corporation. Windows 95 is a product and registered trademark of Microsoft Corporation.
DS72 HOST MODULE OWNER’S MANUAL ABOUT THIS OWNER’S MANUAL ABOUT THIS OWNER’S MANUAL This document provides information required for installing and operating your Bay Tech equipment. It should allow the user to connect, power up, and access an applications menu where peripheral equipment can be controlled. We recommend reading this manual carefully, while placing special emphasis on correct cabling and configuration.
TABLE OF CONTENTS ABOUT THIS OWNER’S MANUAL........................................................................ iii INTRODUCTION TO THE DS72 NETWORK INTERFACE MODULE ................. 1 PROGRAMMABLE FEATURES OF THE DS72................................................................................................................................ 1 DS72 QUICK START ................................................................................................ 3 EIA-232 SERIAL CONNECTION................
TABLE OF CONTENTS REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY ............... 24 FCC RADIO FREQUENCY INTERFACE STATEMENT...................................... 25 APPENDIX A: SPECIFICATIONS ......................................................................... 26 APPENDIX B – MODEM COMMANDS................................................................. 27 INDEX .....................................................................................................................
DS72 HOST MODULE OWNER’S MANUAL INTRODUCTION TO THE DS72 HOST MODULE INTRODUCTION TO THE DS72 NETWORK INTERFACE MODULE The DS72network interface module is a primary user interface for use with the BayTech DS-Series and DS-RPC units. The DS72 allows network users operating on a device using a TCP/IP stack with an ethernet connection, to access the main DS units, serial I/O modules, and (in the case of the DS-RPC) remote power switches. It also allows remote access via external modem to the serial port.
DS72 HOST MODULE OWNER’S MANUAL INTRODUCTION TO THE DS72 HOST MODULE Activity Timeout Carriage Return Translation Break Length Unit ID Provides a timeframe for unit disconnect due to inactivity from 1 to 120 minutes. Default = 0 (disabled Enables the Telnet processor to strip linefeeds or nulls which follow carriage returns. Default = disabled. Provides the time frame, for a break command, in msecs, from 1 to 9999 msecs. Default = 350 msecs. Unique ID for DS72 module.
DS72 HOST MODULE OWNER’S MANUAL DS72 QUICK START DS72 QUICK START This section describes the basic steps required to set up and configure your DS72. If you need to acquaint yourself further with the setup, configuration, and operations, see “Detailed Operations and Configuration” beginning on page 8. GETTING STARTED Before the DS72 can be used within a network, there are a few parameters which must be configured.
DS72 HOST MODULE OWNER’S MANUAL DS72 QUICK START Copyright(C) Bay Technical Associates 1998 DS-72 Data Switch Series - Telnet Host Module Revision F.1.00 Module 1 Status..........................1 Serial Port Configuration.......2 Port Device Name................3 Port Select Code................4 Attention Character.............5 Disconnect Timeguard............6 Connect Port ID Echo............7 Login Setup.....................8 Network Port Configuration......9 Unit ID.........................
DS72 HOST MODULE OWNER’S MANUAL INSTALLATION INSTALLATION UNPACKING Compare the unit and serial number of the equipment you received to the packing slip located on the outside of the box. Inspect equipment carefully for damage that may have occurred in shipment. If there is damage to the equipment or if materials are missing, contact BayTech customer service at 228-4678231 or call toll free inside the United States at 800-523-2702.
DS72 HOST MODULE OWNER’S MANUAL CABLING CABLING RJ-45 CABLES AND ADAPTERS IMPORTANT: The DS72 network interface module has an RJ-45 port which uses an 8-pin crossed modular cable to connect to a local EIA-232 device such as a computer terminal or external modem. Most serial computers do not have RJ-45 connections; therefore an adapter is provided with this unit to convert from a DE-9 connector to an RJ-45 connector (Bay Tech Part No. 9FRJ45PC-4).
DS72 HOST MODULE OWNER’S MANUAL CABLING RJ-45 RJ-45 CONDUCTOR PIN PIN 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 COLOR COLOR BLUE ORANGE BLUE BLACK BLACK RED RED GREEN GREEN YELLOW BROWN YELLOW GRAY Fig 4: Crossed 8-pin Modular Cable BayTech Part No. RJ08X007 Fig 5: DE-9 PC Serial Port Adapter BayTech Part No.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION DETAILED OPERATION AND CONFIGURATION The following section, “Detailed Operation and Configuration,” provides a detailed approach to accessing, operating, and configuring the DS72 network interface module. NOTE: It is important that you type all commands correctly. Any combination of wrong entries results in an error message. ACCESSING MAIN MENU Apply power to the module. The following header and main menu appear: Data Switch Series - F.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION , then $CONFIG followed by . This will allow access to the configuration menu for that module. Once configuration is complete, type X for “Exit” followed by . To access the main menu, type the attention character five times. NOTE: You must exit main menu to send ASCII character string commands. NOTE: While operating using the ASCII Character String method, consider placing the DSSeries in binary mode.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION DS72 CONFIGURATION If you are using the Menu Selection Method, select C, “Configure,” followed by from the DS72 Main Menu. The following selection menu appears: Configuration Module 1........................1 Module 2........................2 Module 3........................3 Select Port.....................S Exit............................
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Login Setup : Header is.......................Enabled Password is.....................Disabled Menu is.........................Enabled Auto Connect Port is............Module 3,Port 1 Auto Connect is.................Disabled SERIAL PORT CONFIGURATION Port 1 Device Name EIA-232 Save.......1 Baud Rate..2 Word Size..3 Stop bits..4 DS72 modules perform data rate conversions for devices using different serial configurations .
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Port 1 Device Name EIA-232 Save.......1 Baud Rate..2 Word Size..3 Stop bits..4 Baud Rate 115.2K Module 1 Serial Port Configuration : Word Stop Parity Xon/ Size Bits Xmit 8 1 None Off Xoff/ Recv Off Line DTR High Drive RTS High Parity............5 Xon/Xoff..........6 RTS Line Driver...7 DTR Line Driver...8 Enter Request : Set Word Size by selecting #3, “Set Word Size.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Select #3, “Port Device Name,” followed by . The DS72 module responds: Port 1 Device Name EIA-232 Baud Rate 9600 Module 1 Serial Port Configuration : Word Stop Parity Xon/ Size Bits Xmit 8 1 None Off Xoff/ Recv Off Line DTR High Drive RTS High Enter Port Device Name (Max. 16 characters): or press ENTER for no change ...........: Enter a new port device name up to 16 characters.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION ATTENTION CHARACTER The Attention Character is a character used in sequence to invoke the main menu. Default Attention Character is a semicolon (;). From the configuration menu, select #5, “Attention Character,” followed by . The host module displays the current attention character and asks if you want to change. Attention Character is............
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION by . The DS72 module presents the current status of Port ID Echo and asks if you want to change: Port ID Echo is....................Disabled Change It? (Y/N): Type “Y” followed by to toggle Connect Port ID Echo or “N” for no followed by . If you answer yes, the DS72 module responds: Port ID Echo is...................Device Name Disable Port ID Echo..............1 Use Module, Port Number...........2 Use Device Name...........
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Header is......................... Disabled Enable? (Y/N, CR for no change): Type “Y” followed by if you want to enable Header status. Type “N” followed by if you want to disable Header. Enter for no change. Password To change Password or Enable/Disable Password upon login, select #2, “Password,” from the selection menu, followed by . Default Password is BTA, disabled. The DS72 module responds: Change Password........
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION If enabled, the following header and menu appears: Bay Technical Associates Unit ID: BAYTECH DS72 Port Select Code: $BT Attention Character: ; Device A (2,1)...........1 Device B (2,2)...........2 Device C (2,3)...........3 Device D (2,4)...........4 DS-RPC (3,1)...........5 Configure.......................C Status..........................S I/O Modules Reset...............RM Unit Reset......................RU Exit........................
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Enter the module to connect automatically, followed by . Enter the port to connect automatically, followed by . The DS72 module stores the new settings in non-volatile memory and returns to the Auto Connect Port menu. Toggle Auto Connect Port feature by selecting #2, “Enable/Disable,” from the Auto Connect Port menu followed by . The DS72 module displays the current auto connect port status and asks if you want to enable.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Enter the Module IP Address (Example: 200.4.3.50), followed by . The DS72 resumes the configuration menu.Default Module IP Address is 0.0.0.0. If you fail to enter the Module IP Address in dotted decimal form, the DS72 responds again: Enter Module IP address in dotted decimal form: The DS72 responds indefinitely with the same request until the Module IP Address in entered in the correct form.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Enter Gateway address in dotted decimal form: The DS72 responds indefinitely with the same request until the Gateway address is entered in the correct form. Activity Timeout When this option is enabled, the DS72 will automatically disconnect, if there is no activity, after the programmed amount of time. Default is 0 (disabled). The enabling input can be from 1 to 120 minutes.
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Enter the desired Unit ID, followed by The DS72 module stores the changes in non-volatile memory and returns to the configuration menu. STATUS From the main menu, type “S” to select “Status,” followed by . The following menu appears: DS-72 Status Menu. Enter selection, CR to exit. 1)...System 2)...Network Interface 3)...
DS72 HOST MODULE OWNER’S MANUAL DETAILED OPERATION AND CONFIGURATION Allow approximately 10 seconds for the unit to reset. ASCII Character String To reset the DS-Series Unit using the ASCII character string method, send the following command: $BTRESET DIAGNOSTICS To detect hardware, cabling, or configuration problems upon initialization of power, the DS72 executes a diagnostic sequence. To help determine the cause of the problem, the DS72 has a CX LED located on the front panel of the unit.
DS72 HOST MODULE OWNER’S MANUAL REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY TECHNICAL SUPPORT BayTech has a staff of applications engineers on duty to assist you from 7 a.m. to 6 p.m. (CST or CDT), Monday through Friday. If you have problems installing, setting up, or operating your Bay Tech product, please contact BayTech’s technical support office. For information on all of BayTech’s data communication products, contact our Web Site at the address shown below. Bay Technical Associates, Inc. 200 N.
DS72 HOST MODULE OWNER’S MANUAL REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY REPACKAGING, SHIPPING AND RETURNING TO THE FACTORY If your Bay Tech unit needs service, upgrade, or repair, return it to BayTech. Before dismantling your equipment or before returning the unit for any reason, always call BayTech. The user should never attempt repairs on this unit.
DS-SERIES OWNER’S MANUAL FCC RADIO FREQUENCY INTERFACE STATEMENT FCC RADIO FREQUENCY INTERFACE STATEMENT This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with this manual, may cause interference to radio communication. This equipment has been type tested and found to comply within the limits for a Class A digital device pursuant to Subpart J of Part 15 of FCC rules.
DS72 HOST MODULE OWNER’S MANUAL APPENDIX A SPECIFICATIONS DS72 Network Interface Module EIA-232 Serial Port 8 pin modular connector (RJ-45) Environment 0° to 70°C 5% to 95% humidity Indicators 1 green LINK integrity LED 1 red RX/TX Network Activity LED 1 red CX LED Interface Transmission Protocols Frame Types Handshaking Baud Rate EIA-232, Ethernet, 10Base-T Asynchronous TCP/IP Ethernet II and SNAP (802.3) CTS/DTR; selectable Xon/Xoff 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 76.
DS-SERIES OWNER’S MANUAL APPENDIX B APPENDIX B MODEM COMMAND SUMMARY U.S. ROBOTIC MODEMS COMMAND INTERPRETATION Fixed Serial Port Rate (default) AT&B1 AT&C1 Normal CD Operations (default) AT&D2 Normal DTR Operations (default) ATS0=1 Auto answer telephone line in 4 or fewer rings ATE0 Modem does not display keyboard commands.
DS-SERIES OWNER’S MANUAL iNDEX INDEX A Accessing Main Menu ASCII Attention Character Auto Connect Port M 8 9, 10 8, 14, 15, 16 17, 18 B Baud Rate Binary Mode break condition 7 6 8, 9, 10, 11, 12, 13, 16 14, 15 ii 4, 8 1 4, 8, 19, 27 6 22 14 26 3 19 F Factory Default FCC Statement 13, 19 25 G Gateway 18, 19, 20 H Header Host communications 15, 16 1 I Installation Interface IP Address 5 25 18, 19, 22 L LED Login Setup O Operation 8, 10, 11, 12, 13, 16 Parity Password Port Device Name Port Se
DS-SERIES OWNER’S MANUAL iNDEX 29