Specifications

245 Cruiser Owner’s Manual Supplement Chapter 5: Plumbing
33
Winterizing the Water Heater
1. Turn Off the water
heater breaker.
2. Disconnect the hose (A)
attached to the pressure
relief valve (B), and
drain any water from
the hose into the bilge
or into a bucket.
3. Open the pressure relief
valve (B).
4. Open the drain valve
(C).
5. Attach a tag to the
water heater breaker to
indicate that the tank is
empty.
NOTE: Your boat came
with a tag attached to the
water heater breaker. It
is suggested that you
keep this tag and re-use
it when winterizing.
Leave the pressure relief
and drain valves Open
until you fit out your
boat after storage.
WATER HEATER DAMAGE HAZARD!
NEVER turn On the water heater breaker on the 110-volt AC master panel while the water
heater tank is empty.
Even brief water heater operation with a dry tank WILL damage the heating elements.
Warranty replacements will NOT be made on elements damaged in this manner.
To prevent damage to the water heater after winterizing, always label the breaker switch on
the 110-volt AC master panel as ’winterized’.
CAUTION
!
NOTICE
The freshwater system MUST be drained BEFORE winterizing the water heater (see the
Freshwater System Winterization Instructions on the previous page).
A
B
C
"WATER HEATER IS EMPTY"
TAG ATTACHED TO WATER
HEATER CIRCUIT BREAKER
BY BRAND AND MODEL.
NOTE: TYPICAL WATER
HEATER SHOWN. LOCATIONS
OF FITTINGS MAY VARY