Instructions / Assembly

9
Store upright with
Protective Cap
CLOSED
Cylinder
Valve
To check your local codes, see your local LP gas dealer or natural gas company. This cooker is not intended to be connected
to a natural gas supply line.
When purchasing or exchanging a cylinder for your gas cooker, it must be constructed and marked in accordance with the
specifications for LP gas cylinders by the U.S. Department of Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods as applicable with a listed over-
filling device (OPD).
The cylinder must also be equipped with:
• A shut-off valve terminating in a Type-1 gas cylinder valve outlet.
• A Type-1 valve that prevents gas flow until a positive seal is obtained.
• An arrangement for vapor withdrawal.
• A collar to protect the cylinder shut-off valve.
• A safety relief device having direct communication
with the vapor space of the cylinder.
• A listed Over-filling Prevention Device (OPD).
A protective cap on cylinder Type-1 Outlet.
OPD Handwheel
(Cylinder Valve)
Protective Cap
Type1
Outlet
Safety Relief
Valve
LP GAS CYLINDER SPECIFICATIONS
WARNING
LP GAS CYLINDER
The LP (Liquid Propane) gas cylinder specifically designed to be used with this cooker must have a 20 lb (9.1 kg) capacity
incorporating a Type-1 cylinder valve and an over-filling protection device (OPD).
• DO NOT connect this cooker to an existing #510 POL cylinder valve with Left Hand Threads. The Type-1 valve can be
identified with the large external threads on the valve outlet.
• DO NOT connect to a propane cylinder exceeding this capacity.
• DO NOT connect to a cylinder that uses any other type of valve connection device.
WARNING
• Turn off the cylinder valve when your cooker is not in use.
• Handle the LP gas cylinder with care.
• Always secure the LP gas cylinder in an upright position.
• Never connect an unregulated LP gas cylinder to your cooker.
• DO NOT expose LP gas cylinders to excessive heat or ignition sources.
• Read and follow all warnings/instructions that are on the
cylinder and that accompany this product.
• Allow only qualified LP gas dealers to fill or repair your LP gas cylinder
• DO NOT allow the LP gas cylinder to be filled beyond 80% capacity.
NOT SUPPLIED WITH THIS COOKER
DANGER
• Never store spare LP gas cylinder near your cooker. This could cause excess pressure to be expelled
through the vapor relief valve resulting in fire, explosion, or severe personal injury, including death.
NOTE: PROPANE GAS IS HEAVIER THAT AIR AND WILL COLLECT IN LOW AREAS. PROPER VENTILATION IS
EXTREMELY IMPORTANT
• Keep the ventilation opening(s) of the LP gas cylinder enclosure free and clear from obstruction and debris.
• DO NOT insert any foreign objects into the valve outlet. Damage to the back-check could result.
A damaged back-check can cause a leak, possibly resulting in explosion, fire, severe personal
injury, bodily harm or death.
Use and store cylinder
in upright position