Using Domes on Digital Sprite Multiplexers Contents Page Pelco Ultrak Diamond KD6 Dome Direct by RS485 Ultrak Diamond KD6 Dome switch settings VCL Orbiter and Jupiter Microsphere Domes Direct by RS485 JVC TK-C675 or TKC-C553E Dome Direct by RS485 Using a TK-C675E (U) Using a TK-C675BE(BU) Dennard 2050 Dome Direct by RS485 Dennard 2050 Dome by BBV Coaxial Telemetry Panasonic WV-CS850 / WV-CS854 Direct key presses Presets Patrol & Autopan Relay Outputs Sensormatic Speed Dome Pelco Spectra II 'P' Protocol
Pelco The DSL/DS generates Pelco Extended Coaxitron Protocol but does not support the following: • Random Scan function • Auto Scan function These functions are only available via a Pelco controller. Features available to DS/DSL using Pelco coaxial. Variable speed Pan/Tilt Zoom/Focus 32 Presets (00 to 31) Auto 180° Flip Goto 0 Degree position. Presets Recall Presets by pressing the button. Once a box appears on screen that displays: Goto Preset. Enter Preset number.
Ultrak Diamond KD6 Dome Direct by RS485 The Ultrak dome needs to be set to Maxpro Emulation. See Table 1. For correct switch settings. You have full access to the dome menu and functions by the DS/DSL. The only function that is not possible to use is the privacy zones and iris open/close of the camera (Not in menu option). Also Preset (Preshot) names aren't available. Dome features via DS/DSL: Variable speed Pan/Tilt. Zoom/Focus, Autofocus, Auto exposure, Backlight compensation. 460TVL 1.7 lux (0.
Presets Recall Presets by pressing the button. Once a box appears on screen that displays: Goto Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Save Presets by pressing and holding the button. Once a box appears on screen that displays: Save Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Cancel Presets by double pressing the button.
Table 1 Ultrak KD6 Switch settings * Please refer to Ultrak Documentation for latest switch settings * R Firmware st M Firmware 1 August 2001 th L Firmware 25 April 2001 th K Firmware 24 January 2001 Control System S4-1 S4-2 S4-3 Maxpro Closed Open Open S4-4 Open th J Firmware 24 October 2000 Control System S4-1 S4-2 S4-3 S4-4 Maxpro Closed Open Open Open th H Firmware 14 August 2000 Control System S4-1 S4-2 S4-3 S4-4 Maxpro Open Closed Open Open ** Using a DSL with Ultrack Driver
VCL Orbiter and Jupiter Microsphere Domes Direct by RS485 The dome doesn't have any in-built menus so the DSL/DS generates 3 different menus. Dome features via DS/DSL: Variable speed Pan/Tilt/Zoom up to 400°/second (Orbiter) with variable speed zoom lens. Zoom/Focus, Autofocus, Auto iris, Auto Mono/Colour, Auto IR, Auto 180° tilt. Mono, Colour and Colour/mono options. Low light capability, 0.4 lux Colour mono with full frame intergration.
Menu 3 VCL Autopan Data > > > > > > > > > > > > Preset ------------- Speed 00 00 00 00 00 00 00 00 00 00 00 00 Dwell 001 001 001 001 001 001 001 001 001 001 001 001 When you press the key recall the presets contained within this table. Up to 16 Presets can be used. Preset (00 - 99) Recall preset number. Speed (00 -99) Speed of travel between presets. (00 slow - 99 fast) Dwell (001 - 240) Time taken (In Seconds) before moving on to the next Preset in the list (Nearest 2 seconds used by head).
JVC TK-C675 or TKC-C553E Dome Direct by RS485 If using a TK-C675 model there are two types of JVC telemetry protocol, Type 1 and Type 2, which must be selected in the Alarms and Presets menu. Default is Type 2. Type 1 TK-C675E TK-C675U -- Type 2 TK-C675BE TK-C675BU TK-C553E Dome features via DS/DSL: JVC TK-C675 1/3 inch 480 TVL Colour CCD Camera, 24V AC Digital Signal Processor 64 Preset positions (Preset 00 - 63) 360 degree endless panning Sensitivity 0.9 lux at f1.
The Domes Internal Switch settings should be as follows: Disp on Multi-drop on Simplex on Sync Int Machine ID set the camera number 1- 16 Using a TK-C675E (U) If using the earlier TK-C675E (U) then this doesn't have any internal menus. In order to change any settings you will need to use the goto Preset command. JVC Commands obtained directly by using the Preset command. Recall Preset by pressing the goto button. Once a box appears on screen that displays Goto Preset. Enter Preset number.
Using a TK-C675BE(BU) Using the later model this has a in built dome menus. Accessing the dome menu In order to access the domes Menu using the DS/DSL press the <* Command> button. A key assistance box appears which says which keys are used to navigate the following dome menu, press
Dennard 2050 Dome Direct by RS485 This has its own Dome menu that can be accessed by the DS/DSL. Dome features via DS/DSL: Variable speed Pan/Tilt. Zoom/Focus, Autofocus. 18 x 1 zoom lens, 4.1mm to 73.8mm zoom; F1.4 to F3.0. Autofocus with manual override. 768 horizontal x 494 vertical, pixels. More than 470 TVL.. 0.05° to 300° / second max (both Pan and Tilt). 180° Auto Flip. At 90° tilt down. Up to 90 Preset positions with programmable titles.
Dennard Commands obtained directly by using the Clear Preset command. Cancel Presets by double pressing the button. Once a box appears on screen that displays: Clear Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Clear Preset Number 90 91 92 93 Domes Version 1.
Dennard 2050 Dome by BBV Coaxial Telemetry If using a 2050 by BBV Coaxial telemetry then the Dennard uses a BBV RX100 interface unit. Dome features via DS/DSL: Automatic return to preset or tour mode. 18 x 1 zoom lens, 4.1mm to 73.8mm zoom; F1.4 to F3.0. Autofocus with manual override. 0.05° to 300° / second max (both Pan and Tilt). 180° Auto Flip. At 90° tilt down.
Panasonic WV-CS850 / WV-CS854 This has its own Dome menu that can be accessed by the DS with Application software 2.0 (015) or above. Dome features via DS/DSL: Variable P/T/Z Full menu operation. 64 presets.
Dome Menu ** SET UP MENU ** PRESET 1* Ê MAP Ê HOME POSITION 1 SELF RETURN OFF AUTO MODEOFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON LOCAL/REMOTE LOCAL SPECIAL1 Ê CAMERA Ê RS485 SET UP Ê Ê Indicates there is a submenu.
Presets Recall Presets by pressing the button. Once a box appears on screen that displays: Goto Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Saving a preset is done by entering the Panasonic's OSD Menu. Move the dome to the position where you want to store the preset. In order to access the domes Menu using the DS press the <* Command> button.
Once you have changed the parameters move the cursor to PRESET NO. 2 POSITION SET Ê Press on the DS keyboard you will see a new screen. ** POSITION 2 ** PAN/TILT àPUSH SET ZOOM/FOCUS àPUSH SET PAN OFFSET SET ß + 0.0 à RET 2 Use the joystick (ß,á,â,à) to move the cursor around the menu. Highlight PAN/ TILT àPUSH SET then press . The screen will change to.. ** POSITION 2 ** PAN/TILT àPUSH SET ZOOM/FOCUS àPUSH SET U TILT D / L PAN R PAN OFFSET SET ß + 0.
For further information please refer to the Panasonic documentation. ** If a preset is already stored in a position then you will need to delete the preset before you can store a new preset in the same position ** Deleting a Preset is done by entering the Panasonic's OSD Menu. In order to access the domes Menu using the DS press the <* Command> button. A key assistance box appears which says which keys are used to navigate the following dome menu, press
Learning the PATROL Enter the Panasonic's Menu. By the <* command> key. Goto SPECIAL1 Ê using the joystick (ß,á,â,à). Press the key. Change menu item to PATROL LEARN Press and hold the <* Command> button to exit from the menu. You will now have LEARNING in the middle of the screen. The dome is now learning the PATROL use the joystick (ß,á,â,à) and , . To finish the PATROL either wait until LEARNING disappears from the screen or go back into the Panasonic's Menu.
Assigning keys to operate relay outputs (CNT-CLS 1-2) It is possible to assign the , or keys to operate different Relay outputs on the Alarm Output connector. Default Settings. DM Key , latching ON/OFF , momentary close , latching ON/OFF Panasonic function Not assigned Close Aux 1 output Close Aux 2 output Enter the Domes menu press the <* Command> button.
Sensormatic SpeedDome Camera Dome This has its own Dome menu that can be accessed by the DS with Application software 2.0 (015) or above. Dome features via DS/DSL: Variable P/T/Z Full menu operation. 50 presets. Presets 1 - 7 Programmable in Menu and DS. Presets 8 - 50 programmable by DS. RS422 2 wire Control 3 Programmable patterns. 1 Spiral pattern. Dome Connection Connection from the Digital Sprite is from the Serial 9 way D- type Female to the Sensomatic Mounting Base IO Board.
Dome Menu DOME CONFIGURATION MENU PAN/TILT/ZOOM CAMERA / LENS FUNCTIONS ALARMS / AREAS / HOME / PZ ON-SCREEN TEXT DISPLAY LANGUAGE PASSWORD RESET TO FACTORY SETTINGS QUIT WITHOUT SAVING EXIT AND SAVE CHANGES Direct Key Presses: Sensormatic Key/Function Digital Sprite Keyboard press Starting the Dome Configuration Utility (Enter Dome Setup) Exit Dome Menu Enter Setting / Open a submenu (Enter) Move the Cursor Select a parameter Focus near Focus far Zoom in Zoom out Spiral pattern Patterns 1 - 3 / Patrols
Presets Recall Presets by pressing the button. Once a box appears on screen that displays: Goto Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Save Presets by pressing and holding the button. Once a box appears on screen that displays: Save Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. It isn't possible to Cancel Presets on the Sensormatic dome.
Pelco Spectra II SD5 Dome This has its own Dome menu that can be accessed by the DS with Application software 2.0 (021) or above. Dome features via DS: Variable P/T/Z Full menu operation. 64 presets. RS422 2 wire Control Randon Scan Auto Scan Frame Scan Dome Connection Connection from the Digital Sprite is from the Serial 9 way D- type Female to the Pelco Mounting Base Board. Must be set for Pelco 'P' protocol and 9600 Baud. See Pelco Installation guide for more information.
Accessing the dome menu In order to access the domes Menu using the DS press the <* Command> button. A key assistance box appears which says which keys are used to navigate the following dome menu, press
Presets Recall Presets by pressing the button. Once a box appears on screen that displays: Goto Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Save Presets by pressing and holding the button. Once a box appears on screen that displays: Save Preset. Enter Preset number. Type in the Preset number by using cameras 1 - 10. Camera 10 being 0. Cancel Presets by double pressing the button.
Programming Zones / Sector Access the domes Menu using the DS press the <* Command> button. A key assistance box appears which says which keys are used to navigate the following dome menu, press
To learn the Patrol / Pattern mode Access the domes Menu using the DS press the <* Command> button. A key assistance box appears which says which keys are used to navigate the following dome menu, press
Appendix Obtaining the DS/DSL Telemetry Drivers Versions First Select the Serial Telemetry Type in the System Options menu page. Change this to the type you are using e.g. JVC, Ultrak, VCL etc. Move the cursor to Serial Telemetry Type and wait 20 seconds, the version number should then be displayed. Domes Version 1.3 23 April 2002 Page 29 of 29 I.