Installation guide
TX1500 Manual V5.1 April 2014 Page 13 of 36 TX1500 MATRIX
MATRIX DIAGNOSTICS
The matrix STATUS led indicates system operation as follows:
Flashing Dimly The matrix is powered with at least one Keyboard connected. Use 58# to display the
Keyboard numbers that the matrix has detected on the BBUS.
Mainly OFF, 1 second ON The matrix is powered with no Keyboards connected. – If Keyboards are connected
then make sure that each Keyboard address is unique between 0 – 3. Keyboards
sharing an address will cause the matrix to ignore both Keyboards with
unpredictable results.
OFF The matrix is powered with no Keyboards connected or the matrix is not powered or
has an internal fault. If the power supply seems fine then please contact technical
support for further assistance.
Several commands exist that allow on site diagnostics. These commands must be entered from Keyboard 1 and
display results on monitor output 1.
51# Display the matrix firmware version, number of resets and watchdog resets.
TX1500 Version shows the matrix firmware version number ie 2.3
resets show the number of times that the system has lost power or the menu has been accessed.
watchdogs show the number of times the matrix watchdog has reset the matrix. A high figure here can
indicate that there may be interference or power fluctuations.
55# Coaxial telemetry on.
With normal operation, the coaxial telemetry is only transmitted to a receiver whilst a camera is being
controlled. After a short period the telemetry transmission is stopped. This is prevent interference to sync
separators in DVRs etc. When trouble shooting telemetry problems the telemetry should be on all the time
so the 55# command would be used and then the receiver CABLE and ERROR leds inspected. Pressing #
again will stop the telemetry transmission.
56# Display the status of matrix switch SW1, the display shows a HEX number which corresponds to the switch
settings for SW1. The number is displayed whilst the # key is pressed. Releasing the # key will clear the
number from the screen.
Number displayed SW1 switch
0 1 - 6 OFF
1 1 ON
2 2 ON
4 3 ON
8 4 ON
10 5 ON
20 6 ON
When more than 1 switch is ON then the number displayed will the sum of the values of all switches that are
ON, ie. 1,2 ON, display shows 03, 1,2,3,4 ON displays 0F
RS422 telemetry directly from the TELEMETRY port and should not normally be selected.
Example numbers that could be displayed
0 = normal mode
1 = DIXONS mode – This is a special mode developed for DSG driving Mark Mercer
57# Display the status of matrix switch SW2 as per 56#.
2A = SW2-2/4/6 ON = FACTORY INITIALISATION on a power up. This is used to clear any programming
and load default values. Useful if the matrix has had a corrupted programming. Once powered up turn all
SW2 switches OFF again to prevent further accidental initialisations.
58# Display number of Keyboards or BBUS/I-F with addresses connected to the matrix along with the software
version of each Keyboard or BBUS/I-F.