BBV 1-2-1 Protocol Converter Installation Guide BBV single camera protocol converter Software version CONV3V41 Building Block Video Ltd 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU, UK Tel: + 44 (0) 1323 842727 Fax: +44 (0) 1323 842728 www.bbvcctv.
BBV_1-2-1 _Protocol_converter_manual_V41_November_2013 Page 2 / 40
This manual covers BBV single channel protocol converter software version CONV3_V41 Table of content.
Protocols compatible with the BBV 1-2-1 converter: 360 Vision BBV 422 CBC SMD20 Chugai Conway COP (Pelco D or P) Dennard 2050 DM DTMT (using TAD3 with special s/w) Forward Vision Mic1-300/400 Ganz ZC-S122/123 JVC 676 LG dome (Pelco D) Mark Mercer Meyertech ZVR510 VICTA protocol Molynx 250/260 NIO D86/Intercepter (Pelco D) Panasonic CS850/860 Pelco D Pelco P Philips RS232/485 (bi-phase via Philips LTC8780/50) Photoscan fixed speed pan/tilt Samsung 641/643 dome 421P camera Sanyo VCC9200P Sensormatic RS422 (U
PROG INK1 BBV LED guide SW3 SW2 PCB 02005 Iss 4 SW1 ON ON ON 1 2 3 4 5 6 7 1 8 1 2 3 4 5 6 7 2 3 4 5 6 7 GREEN LD1 - data IN 8 8 SW4 SW1 - termination YELLOW LD2 - data ERROR ON ON 1 J3 J7 J4 RS422/485 INPUT RS232 DEBUG RS422/485 J1 OUTPUT 2 3 4 5 6 7 RED LD3 - data OUT 8 J6 DATA In Termination ON Terminated 3/4 DATA Out Termination ON 5 Terminated Not used 6/7 MUST BE ON 8 Not used LD3 SW4 output protocol.
GND RS232 OUT RS232 IN +V OUT GREEN BROWN / WHITE BROWN BLUE / WHITE BLUE GREEN / WHITE ORANGE ORANGE / WHITE BROWN BROWN / WHITE GREEN BLUE / WHITE GREEN / WHITE BLUE Page 6 / 40 BBV_1-2-1 _Protocol_converter_manual_V41_November_2013 ORANGE ORANGE / WHITE Fig 2 System Layout 5 nc 4 nc 3 TA/+(OUT) 2 TB/-(OUT) 1 GND
Address numbering Address numbering is limited to the number of addresses supported by the selected protocol; the maximum number of addresses that can be supported is 128. For example, a protocol that supports 256 addresses would support a maximum of 128 addresses when used with the BBV 1-2-1 converter. Camera 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52.
63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 99. 100. 101. 102. 103. 104. 105. 106. 107. 108. 109. 110. 111. 112. 113. 114. 115. 116. 117. 118. 119. 120. 121. 122. 123. 124. 125. 126. 127. 128.
SW4 (1 - 6) Output Protocol & Baud Selection for V41 software PROTOCOL 1.SELF TEST 2.DEBUG MODE 3.360 VISION 4.BBV RS422 6.CHUGAI SMD20 7.CHUGAI ZC- S122 8.CONWAY 9.COP DOME (PELCO P/D) 10.DENNARD 20xx series 11. DM DTMF via TAD3 (Camera select sent every command) 12. DM DTMF via TAD3 (Camera select only sent if camera number changed) 13.FORWARD VISION 14.JVC TK-C676 15.LG DOME (PELCO D) LPT-OI551HQ/OI553HQ 16.MARK MERCER 17.MEYERTECH VICTA 18.MOLYNX 19. NIO/DYNAPEL INTERCEPTER (Pelco D) 20.
44.VCL 45.VICON 47.VIDECON VCP451 46.VIDECON VHSD860 48.Videotec Ulisse(Pelco D) 49.
RS232 serial port The DB9F connector provides the ability to use a laptop PC to monitor the data being sent out of the BBV 1-2-1 converter via RS232. On power up or if SW2, SW3 or SW4 switches are altered the unit sends the current protocol, baud rate and parity settings. Please be aware that the laptop baud rate and parity must match the settings selected with SW4. If the settings do not match then the laptop display will have no meaning.
The following table shows the possible input and output protocols that are supported with this version of software.
Protocol specific information SW4 360 VISION from BBV Connect dome D+ to BBV 1-2-1 converter TA and dome D- to BBV 1-2-1 converter TB. Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that the dome at the end of a daisy chained RS485 run has the RS485 terminated and the intermediate domes have the RS485 de-terminated.
Repeat step 3 for each point until the last point Step 4 – last tour point.
BBV 422 (9600, N, 8, 1) (adjust SW3 to suit input protocol) SW4 Connect twisted pair as follows:RA + to BBV 1-2-1 convert TA. RA – to BBV 1-2-1 convert TB.
Chugai/Ganz ZC-S122/123 – Fixed at 9600,E,8,1 from BBV and Pelco D/P telemetry only Function Menu ON/OFF SET (whilst in menu) CLR (whilst in menu) TX1500 Procedure 1# 2# 3# Pelco Procedure Go to Preset 61 Go to Preset 62 Go to Preset 63 PRESET SEQUENCE PLAYBACK TRACE AUTOPAN 1 PATROL 2 PATROL AUTOPAN Go to Preset 66 Go to Preset 67 Go to Preset 68 AUX 1 OUTPUT ON/OFF AUX 2 OUTPUT ON/OFF LIGHTS WIPER 1 AUX 2 AUX SW4 Notes: Connect dome A/+ (pin 1, BROWN) to the BBV 1-2-1 converter TA and dome B/-
CONWAY dome from BBV and Pelco D/P telemetry only SW4 Connect the twisted pair as follows: Dome A to BBV 1-2-1 converter TB Dome B to BBV 1-2-1 converter TA The following functionality is provided: Variable speed Pan/Tilt Zoom/Focus/Iris 64 preset positions Preset tour 1 & 2 playback only Wash/WIPE/LIGHTS (IR Filer ON/OFF) Privacy enable, disable Additional dome features Dome Function ENABLE PRIVACY DISABLE PRIAVCY Tx1000 Keystroke hold # and tap WASH hold # and tap AUTOPAN TX1500 Keystroke 2# 3# Pelco
COP PELCO D or PELCO P from BBV and Pelco D/P telemetry only Connect the twisted pair as follows: dome RS485+ (ORANGE) to BBV 1-2-1 converter TA dome RS485- (YELLOW) to BBV 1-2-1 converter TB Baud Rate 2400 9600 Protocol PELCO D PELCO P SW4 SW4/7 Baud SW4/8 Protocol SW4/7 OFF (default) ON SW4/8 OFF (default) ON Set the dome for protocol and baud rate. The default is 2400 baud and Pelco D telemetry. Set the dome address to match the number of the camera input of the matrix.
DM DTMF RECEIVERS USING TAD3 from BBV and Pelco D/P telemetry only.
FORWARD VISION MIC-1300/400 from BBV and Pelco D/P telemetry only Connect the twisted pair as follows: Dome RX A (YELLOW) to BBV 1-2-1 converter TB Dome RX B (WHITE) to BBV 1-2-1 converter TA SW4 (A & B swapped) Set the dome address to match the number of the camera input of the matrix. The following functionality is provided: Variable speed Pan/Tilt Zoom/Focus/Iris 64 preset positions. Patrol (sequence) record.
In addition, the following dome features are supported.
JVC TK-C676 – Fixed at 9600,E,8,1 Function Display menu and EXIT SET (whilst in menu) Toggle Extended Dynamic Range Cycle BW mode, ON/OFF/AUTO Start dome AUTO PATROL As above for ALL DOMES Start dome AUTOPAN Force AUTOFOCUS after zoom SW4 TX1500 Pelco & Mark Molynx Procedure Mercer Procedure SAVE PRESET 95 Cam on then Prog preset 1 1# GOTO PRESET 33 Cam on then Prog preset 2 2# GOTO PRESET 94 Cam on then Prog preset 3 3# GOTO PRESET 64 Cam on then Prog preset 4 4# GOTO PRESET 97 Cam on then Goto preset 5
SW4 LG DOME (PELCO D) from BBV and Pelco D/P telemetry only.
Meyertech ZVR-510 receiver with VICTA protocol from BBV and Pelco D/P telemetry only. SW4 Connect receiver 422 RX+ to BBV 1-2-1 converter TA and 422 RX- to BBV 1-2-1 converter TB. Set the receiver address to match the number of the camera input of the matrix. The following functionality is provided. Variable speed Pan/Tilt – 8 speeds Zoom/Focus WASH, WIPE, LIGHTS auxiliary outputs 32 preset positions. Menu access and navigation The Meyertech protocol supports 8 speeds for pan and tilt.
SW4 Molynx protocol – Fixed at 9600,E,8,1 Control from BBV and Pelco D/P protocol only Function TX1500 Procedure Pelco Procedure PRESET 1 – 32 As manual As manual WASH, WIPE, LIGHTS TOGGLE MENU ON/OFF As manual 1# As manual Go to Preset 61 TOGGLE JOYSTICK PTZ/MENU CONTROL 2# Go to Preset 62 SET IN MENU DEFINE PRESET PATROL RESET RECEIVER IRIS OPEN or 3 # 4# PROGRAM 99 PRESET Go to Preset 63 Go to Preset 64 Program 99 Preset Notes: Connect receiver + to the BBV 1-2-1 converter TA and receiver
NIO D86/Intercepter (PELCO D) from BBV and Pelco D/P telemetry only SW4 Connect the twisted pair as follows: dome A+ to BBV 1-2-1 converter TA dome B- to BBV 1-2-1 converter TB Dome SW3 – Address, set to match the matrix camera input Dome SW4 – 1 & 8 ON, 2-7 OFF, Selects PELCO & 9600 BAUD The following functionality is provided. Variable speed Pan/Tilt Zoom/Focus/Iris 64 preset positions.
PANASONIC WV-CS850/860 (adjust SW3 to suit input protocol) 9600,N,8,1 or 19200,N,8,1 TX1000 Procedure TX1500 Procedure Molynx Pelco & Mark Mercer Procedure Show/Hide dome Menu # WASH 1# Cam on then Prog preset 1 Go to Preset 61 ENTER (whilst in menu) # WIPE 2# Cam on then Prog preset 2 Go to Preset 62 # AUTOPAN 3# Cam on then Prog preset 3 Go to Preset 63 SPECIAL2 (whilst in menu) # LIGHTS 4# Cam on then Prog preset 4 Go to Preset 64 Send PATROL RUN PATROL 1 1 PATROL Cam on then
PELCO P and PELCO D (adjust SW3 to suit input protocol) Mark Mercer Procedure Function TX1500 Procedure Pelco Procedure Molynx Display Dome Menu 1# Go to Preset 61 Cam on then Prog preset 1 Go to Preset 61 180 degree pan flip (U turn) 2# Go to Preset 62 Cam on then Prog preset 2 Go to Preset 62 Display Technicians Menu 3# Go to Preset 63 SW4/8 MUST BE OFF Cam on then Prog preset 3 Not Supported PATTERN DEFINE (START) 3# Go to Preset 63 SW4/8 MUST BE ON Cam on then Prog preset 3 Go to
Philips RS232/485 (bi-phase via LTC8780/50) (adjust SW3 to suit input protocol) SW4 Depending on the exact model type, Philips domes can be controlled using RS232 or RS485 and bi-phase telemetry. Bi-phase telemetry is a proprietary twisted pair protocol that allows several domes to be daisy chained. A Philips LTC8780/50 1-2-1 converter is required in addition to the 1-2-1 converter when driving bi-phase telemetry.
PHOTOSCAN FIXED SPEED PAN/TILT from BBV and Pelco D/P telemetry only The following functionality is provided: Fixed speed Pan/Tilt Zoom/Focus/Iris WIPE drives the WI aux output WASH drives the WA aux output AUTOPAN drives the A2 output LIGHTS has not been tested due to faulty receiver. SW4 S tar o u tp u t Photoscan receivers are driven using current loop telemetry.
Samsung SCC641/643 dome and SCC421 camera from BBV and Pelco D/P telemetry only SCC641/643 dome Connect dome RXD/+ to BBV Converter TA and dome RXD/- to BBV Converter TB. Set the dome address using the SW500 switch to match the number of the camera input of the TX1500. SW501 all off apart from 3 and 5 to select 9600 BAUD, SAMSUNG protocol and FULL duplex.
Connect dome RS422 IN + to BBV 1-2-1 converter TA and RS422 IN- to BBV 1-2-1 converter TB. Set the dome address to match the number of the camera input of the matrix. The following functionality is provided. Variable speed Pan/Tilt Zoom/Focus/Iris 64 preset positions.
VCL TP – Fixed at 9600,N,8,1 (adjust SW3 to suit input protocol) SW4 Connect dome D+ to 1-2-1 BBV Converter TA and dome D- to 1-2-1 BBV Converter TB. Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the intermediate domes have the RS485 de-terminated. The following functionality is provided.
VCL TP – When using Pelco input protocol Advanced Function 180 degree pan flip (U turn) Program a privacy zone Clear a privacy zone Dome remote reset (power cycle) Add preset position to the tours Remove a preset from the tours Start preset tour 1 – high speed Start preset tour 2 – slow speed Start Learned tour 5 Set Home functions (fixed at 5 minutes) Reset dome to factory. USE CAUTION!! This command will clear all dome configuration including preset positions.
SW4 Vicon Surveyor (adjust SW3 to suit input protocol) Connect dome COMM_IN+ to BBV 1-2-1 Converter TA and dome COMM_IN- to BBV 1-2-1 Converter TB. Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the intermediate domes have the RS485 de-terminated. Select VPS telemetry using dome DIP DIL. The following functionality is provided.
VIDECON VCP451 CAMERA from BBV and Pelco D/P telemetry only Connect the twisted pair as follows: Camera RS485+ to BBV 1-2-1 converter TA Camera RS485- to BBV 1-2-1 converter TB SW4 The following functionality is provided: ZOOM, FOCUS Menu Access Advanced Dome features Dome Function TX1000 Keystroke TX1500 Keystroke Pelco Procedure hold # and tap WASH 1# Go to Preset 61 DISPLAY MENU Use the joystick to navigate the menu or zoom for up/down and focus for left/right Note: Use the MENU switch on the c
VIDECON VHSD 860 DOME (adjust SW3 to suit input protocol) SW4 Connect the twisted pair as follows: Dome D+ to BBV 1-2-1 converter TA Dome D- to BBV 1-2-1 converter TB The following functionality is provided: Variable speed Pan/Tilt Zoom/Focus/Iris 64 preset positions Menu Access (Iris open – Enter Iris Close – Exit) Privacy Menu Access Pattern Tour 1 define and playback, Auto Patrol playback, Frame Scan playback Advanced Dome features Dome Function TX1000 Keystroke TX1500 Keystroke Molynx Pelco & Mark M
VIDEOTEC ULISSE (PELCO D) from BBV and Pelco D/P telemetry only SW4 Connect the twisted pair as follows: Ulisse 485/A to BBV 1-2-1 converter TA Ulisse 485/B to BBV 1-2-1 converter TB Ulisse Switch settings BAUD RATE – 4 ON, 3 OFF, 2 ON, 1 OFF PROTOCOL – 1 ON, 4 ON, ALL OTHERS OFF ADDRESS – 9 ON, 1-8 SETS THE ADDRESS AS ULISSE MANUAL The following functionality is provided: Variable speed Pan/Tilt Zoom/Focus/Iris 64 preset positions.
Vista PowerDome (adjust SW3 to suit input protocol) SW4 Connect dome DATA IN A/+ to BBV 1-2-1 Converter TA and dome DATA IN B/- to BBV 1-2-1 Converter TB. Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the intermediate domes have the RS485 de-terminated. The following functionality is provided. Manual pan/tilt control with 16 speed steps.
Extend your BBV Warranty from 12 months to 3 years As of the 1st September 2008 BBV have offered our customers the opportunity to extend the standard 12 month warranty to 3 years. You must register for the extended warranty within 12 months of the date of manufacture. How to register for the 3 year warranty Registering for the new, longer 3 year warranty term is quick and easy.