Installation guide
BBV_1-2-1 _Protocol_converter_manual_V41_November_2013 Page 14 / 40
12 3456 78
ON
12 3456 78
ON
SW3 SW4
Repeat step 3 for each point until the last point
Step 4 – last tour point. PROGRAM 57 PRESET
3 PRESET (point 3)
4 PRESET (PRESET 4)
32 PRESET (middle speed)
2 PRESET (2 seconds dwell)
The tour is now defined
PROGRAM 57 PRESET (last point)
1 – 64 PRESET (tour point number)
1 – 32 PRESET (preset number)
1 – 64 PRESET (speed)
1 – 64 PRESET (dwell in seconds
Mimic Tour Definition
(AUTOPAN will replay the mimic tour)
PROGRAM 58 PRESET (start definition)
Use joystick and zoon to move dome around
required tour.
PROGRAM 59 PRESET (end definition)
Fast Shutter ON (ANPR mode)
PROGRAM 60 PRESET
Fast Shutter OFF (normal mode)
PROGRAM 61 PRESET
360 VISION from VCL telemetry
Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure
that the dome at the end of a daisy chained RS485 run has the RS485 terminated and the intermediate
domes have the RS485 de-terminated.
The following functionality is provided:
Manual pan/tilt control with 16 speed steps from 1 to 127 (slowest to fastest)
Zoom with Manual Iris and Focus override.
Operating the Zoom will re-enable auto focus and iris after manual adjustment
32 preset positions.
Preset 100 – 127 will program the dome privacy zone 1 – 27. These can be disabled within the VCL privacy
menu by setting the appropriate preset to PRESET. The dome will move to show the privacy scene to allow
toggling the privacy back on by selecting PRIVATE.
Tour definitions are compatible with the VCL programming method 2 including dwell time and speed per
tour point.
The dome home feature can be programmed using the standard VCL control menu.
In addition to the standard functions offered by the VCL control system the following features are available:
Set autoflip mode
program preset 51 followed by
goto preset 1 = autoflip OFF
goto preset 2 = ON tilt at down limit
goto preset 3 = ON when at limit
Set Video Gain/Lift and Sync timing
program preset 52 followed by
iris close/open to increase/decrease GAIN
focus near/far to increase/decrease LIFT
zoom in/out to advance/retard timing
Move joystick when finished.
Set IR Filter mode
program preset 53 followed by
goto preset 1 = mono mode/auto off
goto preset 2 = colour mode/auto off
goto preset 3 = auto/kill colour
goto preset 4 = auto/don’t kill colour
Set Home functions
(fixed at 5 minutes)
program preset 54 followed by
goto preset 1 = Enable to preset 1
goto preset 2 = Enable to patrol 1 (fast)
goto preset 3 = Enable to patrol 2 (slow)
goto preset 4 = Disable home
Unit Reset. program preset 55 twice
Connect dome
D+ to 1-2-1 BBV Converter TA and dome
D- to 1-2-1 BBV Converter TB.