Molynx protocol – Fixed at 9600,E,8,1 Control from BBV and Pelco D/P protocol only
Function TX1500 Procedure Pelco Procedure
PRESET 1 – 32 As manual As manual
WASH, WIPE, LIGHTS As manual As manual
TOGGLE MENU ON/OFF 1 # Go to Preset 61
TOGGLE JOYSTICK
PTZ/MENU CONTROL
2 # Go to Preset 62
SET IN MENU IRIS OPEN or 3 # Go to Preset 63
DEFINE PRESET PATROL 4# Go to Preset 64
RESET RECEIVER PROGRAM 99 PRESET Program 99 Preset
Notes:
Connect receiver + to the BBV 1-2-1 converter TA and receiver - to the BBV 1-2-1 converter TB.
Set the receiver address switches to match the number of the camera input of the matrix.
Molynx receivers can only be controlled when using BBV telemetry into the 1-2-1 converter ie from the BBV
TX1500 or FBM series matrix.
Control of the receiver auxiliary relays is possible using the matrix Wash, Wipe and Lights keys.
Up to 32 preset positions can be programmed and recalled.
Dome mono/colour selection is possible using the LIGHTS button once the mono/colour switching has
been set to MAN in the dome menu.
Preset Patrol Definition.
A single preset patrol can be defined which can contain up to 16 preset positions. The patrol speed and
delay can be programmed as a global for each preset position. Use the following keystrokes.
4#
132 PRESET This is the delay in seconds for all preset positions
132 PRESET This is the speed to move between preset positions
1 is very slow and 32 is full speed
Next up to 16 preset positions, eg for patrol presets 1, 3, 6 and 17
1 PRESET, 3 PRESET, 6 PRESET, 17 PRESET
MOVE JOYSTICK This ends the definition.
To start the preset patrol press 1 PATROL
Improvement added in Version 30
SW4/8 can be used to allow the CAMERA POWER Aux to be operated from AUTOPAN allowing
AUTOPAN control of AC receivers.
SW4/8 ON = enabled this feature, and SW4/8 OFF = disables
SW4