Installation guide

BBV_1-2-1 _Protocol_converter_manual_V41_November_2013 Page 36 / 40
VIDECON VCP451 CAMERA from BBV and Pelco D/P telemetry only
Connect the twisted pair as follows:
Camera RS485+ to BBV 1-2-1 converter TA
Camera RS485- to BBV 1-2-1 converter TB
The following functionality is provided:
ZOOM, FOCUS
Menu Access
Advanced Dome features
Dome Function TX1000 Keystroke TX1500 Keystroke Pelco Procedure
DISPLAY MENU
Use the joystick to navigate the
menu or zoom for up/down and
focus for left/right
hold # and tap WASH
1 #
Go to Preset 61
Note:
Use the MENU switch on the camera to set the following before connecting to the 1-2-1 converter.
CAMERA ID – This must match the camera input of the matrix
PROTOCOL – P/D to allow control (PELCO D, 2400,N,8,1)
The camera uses the zoom and focus functions whilst navigating the menu to make it easier to use the
joystick. Pan generates zoom and tilt generates focus even when not displaying the dome menu. This is
NOT a fault!
For more information please refer to the camera handbook.
SW4