Installation guide

BBV_1-2-1 _Protocol_converter_manual_V41_November_2013 Page 38 / 40
VIDEOTEC ULISSE (PELCO D) from BBV and Pelco D/P telemetry only
Connect the twisted pair as follows:
Ulisse 485/A to BBV 1-2-1 converter TA
Ulisse 485/B to BBV 1-2-1 converter TB
Ulisse Switch settings
BAUD RATE – 4 ON, 3 OFF, 2 ON, 1 OFF
PROTOCOL – 1 ON, 4 ON, ALL OTHERS OFF
ADDRESS – 9 ON, 1-8 SETS THE ADDRESS AS ULISSE MANUAL
The following functionality is provided:
Variable speed Pan/Tilt
Zoom/Focus/Iris
64 preset positions.
Start Patrol
Start AUTOPAN
Menu access and navigation
Additional Dome features
Dome Function TX1000 Keystroke TX1500 Keystroke
Pelco Procedure
DISPLAY MENU
hold # and tap WASH and
navigate using the ZOOM
IN = ENTER, OUT = BACK
1 # and navigate using the
joystick and ZOOM
IN = ENTER, OUT = BACK
Go to Preset 61
AUTO
WASH/WIPE
WASH SW4/8 = OFF
(factory default)
WASH SW4/8 = OFF
(factory default)
3 AUX SW4/8 = OFF
(factory default)
RELAY O1/C1 WASH SW4/8 = ON WASH SW4/8 = ON 3 AUX SW4/8 = ON
WIPE
WIPE WIPE
2 AUX
LIGHTS O2/C2
LIGHTS LIGHTS
1 AUX
START PATROL HOLD 1 TAP PATROL
1 PATROL
Go to Preset 66
AUTOPAN
AUTOPAN AUTOPAN
Go to Preset 67
Note:
WASH function can either control Ulisse relay output O1/C1 or to start the head auto wash/wipe feature.
SW4/8 is used to switch between these modes. The factory setting is with SW4/8 OFF = WASH starts the
auto wash/wipe function.
Head moves to Preset 1, the WASH is activated for a time set in the head menu and then the Wiper
operates for another time configured in the head menu before returning the head to the original position.
If this feature is not required the O1/C1 relay can be controlled instead by switching SW4/8 ON.
For more information please refer to the Ulisse handbook.
SW4