Vista PowerDome (adjust SW3 to suit input protocol)
Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure
that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the
intermediate domes have the RS485 de-terminated.
The following functionality is provided.
Manual pan/tilt control with 16 speed steps.
Zoom with Manual Focus override.
Operating the Zoom will re-enable auto focus after manual adjustment
64 preset positions.
3 tours can be started, TOUR 1 and 2 using 1 PATROL and 2 PATROL and LEARN TOUR 1 with
AUTOPAN.
The tours are defined from the dome menu which is accessed using 1 # as below.
Advanced Function TX1500 Procedure
Pelco &
Mark Mercer
Procedure
Display dome menu 1 # Go to Preset 61
Menu – ENTER 2 # Go to Preset 62
Menu – ESCAPE 3 # Go to Preset 63
Start TOUR 1 1 PATROL Go to Preset 66
Start TOUR 2 2 PATROL Go to Preset 67
Learn 1 playback AUTOPAN Go to Preset 68
SW4
Connect dome DATA IN A/+ to BBV 1-2-1 Converter TA and
dome DATA IN B/- to BBV 1-2-1 Converter TB.