SW1
RS422/485
INPUT
PCB 02005 Iss 4
BBV
SW3
SW4
ON
1234567
8
ON
1234567
8
ON
1234567
8
SW2
J1
J3
J4
J7
J6
RS422/485
RS232
DEBUG
ON
1234567
8
OUTPUT
PROG INK1
LD1
LD2
LD3
POWER
SW4 output protocol.
For settings see page 9.
SW1 - termination
1/2 DATA In Termination
ON Terminated
3/4 DATA Out Termination
ON Terminated
5 Not used
6/7 MUST BE ON
8 Not used
7812 3 546
ON
LED guide
GREEN LD1 - data IN
YELLOW LD2 - data ERROR
RED LD3 - data OUT
SW3 input protocol
12 3456 78
SW2 address selection.
For settings see page 7.
2 - 3 Parity 4 - 5 Baud Rate 6 - 8 Protocol Selection
SW3/2 SW3/3
Parity
SW3/4 SW3/5
Baud
SW3/6 SW3/7 SW3/8
Input Protocol
off off off BBV RS422 (TX1500/FBM) (fixed at 9600,N,8,1)
off off NONE off off 2400
off
off
ON PELCO P
off ON EVEN off ON 4800
ON off ODD ON off 9600
ON ON NONE
off off NONE off off 2400
off ON off PELCO D
off ON EVEN off ON 4800
ON off ODD ON off 9600
ON ON NONE
off ON ON VCL TP (fixed at 9600,N,8,1)
ON off off 360 VISION (fixed at 9600,N,8,1)
off ON 4800
ON off ON VICON (4800,N,8,1 or 9600,N,8,1)
ON off 9600
ON ON off
MOLYNX “D” TYPE TELEMETRY (fixed at 9600,
E,8,1)
ON ON ON DENNARD (fixed at 9600,N,8,1)
SW3/2 SW3/3 SW3/4 SW3/5
SW3/6 SW3/7 SW3/8
ON ON ON ON ON ON ON Mark Mercer (fixed at 9600 N,8,1)
SW3/1 – Output camera address
Off Camera address same as input camera address
ON Output camera address always 1
This can assist with some installations where existing domes/receivers are
addressed as 1 therefore the dome/receiver doesn’t need to be reconfigured.